DST-64T / DST642D Wheel Balancers
48
P/N 5900192 — Rev. F — March 2021
Calibrating the Outer Arm (DST-64T only)
The Outer Arm Calibration makes sure the Outer Arm on the DST-64T is returning correct values.
Note
: The Balancer comes from the factory correctly calibrated. You do not need to perform this
calibration when you receive the Balancer. You only need to perform this calibration if you are
seeing multiple incorrect Wheel balances.
Perform this procedure
without
a Wheel mounted.
To calibrate the Outer Arm
:
Put the 200 mm Outer Arm Calibration Tool into one of the two holes on the Shaft Flange.
Press
and hold
Stop
, then press
OPT
.
CAL-0F
appears.
Place and hold the tip of the Outer Arm on the side of the Shaft Flange (
1
below), then press
ALU
.
CAL-200
appears.
Place and hold the tip of the Outer Arm on the end of the 200 mm Outer Arm Calibration Tool
(
2
above), then press
ALU
.
CAL-END
appears.
The calibration is complete.