Due to our policy of continual improvement, we reserve the right to change specifications without prior notice.

Due to the unique filter formulation and technology, 

conventional hardness test strips or digital meters cannot 

accurately show if the ION media (boiler scale protection 

and hardness reduction media) within the filter has been 

exhausted.
The only way of judging if the ION media is exhausted and 

therefore your filter needs to be replaced is by following the 

subsequent steps:

1. 

Press and hold the 

MENU

 and 

DOWN SCROLL

 button 

simultaneously. 

2. 

You should see a similar information screen to this 

example (

Fig. 7.1

). 

3. 

Take note of the “

WATER USAGE

” value then press the 

POWER

 button to return from this menu.

4. 

Take your GB Clark hardness value and add 2° 

(otherwise use the PPM hardness value and add 30PPM).

Now compare this 

NEW HIGHER

 Clark hardness value against 

the table in conjunction with the 

WATER USAGE

 value.

If the 

WATER USAGE

 figure is higher than the value 

*

REPLACE LITRES

 value in the table then filter will require 

replacing.
Worked Example: 

WATER USAGE

 = 0862 litres, your local 

water hardness is 11 °Clark, add 2 °Clark, then the ‘

REPLACE 

LITRES

’ value in the table for 13 °Clark is  850 litres. In this 

example the ‘

WATER USAGE

’ is more than ‘

REPLACE LITRES

’ 

so the filter requires replacement.
Replacement filters can be obtained by contacting the service 

agent number on the sticker on the top of the boiler.
If the filter does not need replacing (for instance you have 

installed the product in a soft water supply area), you can 

reset the filter reminder beep & indicator bar by pressing and 

holding both the up (

) and down (

) buttons together.

IMPORTANT:

 Before you reset the filter counter you must 

keep a written note of the 

WATER USAGE

 value for when you 

next check your filter. When you come to recheck the 

WATER 

USAGE

 you must add the ‘new’ and ‘previous’ 

WATER

 usage 

totals together and use the combined total against the chart. 
Whilst you get used to your likely personal filter replacement 

schedule, we recommend re-checking filter life frequently to 

protect the boiler from scale.

 STATUS                        2553         0000

 SW:H01                               OFFSET 0361 

 WATER LEVEL                   -2 NORMAL

 HEATING                            - PASS

 PCB                                    - PASS

 NTC                                    - PASS  

 FILTER                               - 6105 HOURS

 WATER USAGE                 - 0862 LITRES

                                     

GB °Clark

PPM

*REPLACE LITRES

5

70

1960

6

90

1610

8

107

1415

9

125

1215

10

143

1065

11

161

945

13

179

850

14

196

775

15

214

640

16

232

590

18

250

545

19

268

510

20

286

480

21

304

450

24

339

405

26

375

365

29

411

335

33

464

250

36

518

220

41

589

185

48

679

170

Fig. 7.1

 

Содержание GEO

Страница 1: ...Instructions for GEO and AGA 4 in 1 tap boiler units BOILER FOR 4 IN 1 TAP Installation Instructions Aftercare Information U110651 02a...

Страница 2: ...he water temperature 7 5 Using the Product 8 6 Descaling the Boiler system 10 7 Filter 12 8 Draining the Boiler system 16 9 Troubleshooting maintenance 17 10 Specifications 20 11 Circuit Diagram 22 12...

Страница 3: ...ater in the tank has cooled to a safe temperature n n WARNING Do not use this appliance if you suspect it or any of its hoses are damaged in any way or is performing differently from how you would exp...

Страница 4: ...device such as a timer or connected to a circuit that is regularly switched on and off by the utility n n Do use any water jet or steam near this appliance n n This appliance should have at least 10m...

Страница 5: ...n Filter reminder Power button Scroll arrows Menu button Status information Time Status indicator Preferred temperature Filling The boiler is filling with fresh cold water to replace the hot water jus...

Страница 6: ...er No water No water supply self diagnostic error confirm water supply is on if problem persists contact service agent on top of boiler PCB Fault PCB self diagnostic error contact service agent on top...

Страница 7: ...backlight brightness between 1 5 3 Once satisfied with the new backlight brightness value hold MENU to store 4 Now the contrast values will flash Repeat for the contrast 5 Hold MENU to store and to e...

Страница 8: ...he least energy efficient setting Shutting down 1 To shut down the product the POWER button should be held when on the normal operation screen for 10 seconds 2 The shutdown screen will appear and usin...

Страница 9: ...st This will happen faster if some of the stored hot water is dispensed and therefore replaced with cold Note it is normal as with any hot water dispenser that thermal energy is lost by the time it is...

Страница 10: ...weeks you should flush 10 litres 3 Hot domestic water This is delivered when the left tap handle is pulled forwards 4 Hot boiled filtered water This is delivered when the HotFob key is moved close to...

Страница 11: ...the HotFob away from the tap L L The HotFob is magnetic to allow you to stick it in out of reach places such as the fridge or the cooker hood With the HotFob away from the tap it can only be used as...

Страница 12: ...switch off the boiler at the front control panel see user guide powering down for more details 2 Wait until the flexible connector B9 has cooled to a safe touch temperature this may take some time Fig...

Страница 13: ...wice repeat the flushing procedure as described in steps 9 to 13 until it subsides n n The boiler descaling agent has been formulated and tested specifically for your appliance no alternative descalin...

Страница 14: ...and has an audible beep when it reaches its estimated end point This is based on average volume and time limits and is designed to help remind you to check the filter Each installation has a differen...

Страница 15: ...e REPLACE LITRES value in the table for 13 Clark is 850 litres In this example the WATER USAGE is more than REPLACE LITRES so the filter requires replacement Replacement filters can be obtained by con...

Страница 16: ...leared cold filtered water will come from the tap The water might at first be discoloured but this is normal and will clear with flushing 10 With a kitchen measuring jug and a clock you must A Flush a...

Страница 17: ...en rinse with warm water and then dry off the tap again to prevent water marks reappearing as the water evaporates Where the tap has a removable aerator on the spout exit it can be removed and cleaned...

Страница 18: ...protective wear to prevent accidental scalding from hot water surfaces and steam 1 Use the HotFob to drain hot water from the tank until no more water can be dispensed 2 Ensure the boiler A1 is turned...

Страница 19: ...e turn off appliance at plug See silver front plate for service contact details The water supply to the boiler is turned off The water pressure is low The inlet filter is blocked with debris Electrica...

Страница 20: ...nearer balance the pressures Domestic hot water temperature is too low Increase the boiler output temperature to help compensate Water is spraying from the spout end Aerator is blocked or partially bl...

Страница 21: ...asks any such naturally occurring tastes in the water Flush the tap for longer before use if the taste persists it is most likely as described Water is cloudy Air in the water You can check for air in...

Страница 22: ...at 3 bar Varies by model refer to tap specifications Note inlet flow limiters are available separately to flow limit the tap if required to meet varying building standards For further detailed inform...

Страница 23: ...bar Maximum cold water pressure 8 bar Filter mesh rating 5 micron nominal rating Primary filter contents Activated carbon block Ion selective media Capacity activated carbon 1700 litres approximately...

Страница 24: ...m Key QTY Description A1 1 Boiler unit A2 1 1 5m Power lead A3 1 Boiler mounting bracket A4 1 Boiler bracket to base unit screw A5 2 Boiler bracket screw A6 1 Data connection lead A7 1 Safety steam ov...

Страница 25: ...tube type C3 1 Filter head including check valve C4 1 Flush Drain pipe C5 1 Filter cartridge C6 2 Filter head screws C7 1 3 8 stem x push fit C8 1 x 1500mm Tube thinner tube type C9 1 x x Push fit eq...

Страница 26: ...dvisory Service All materials WRAS compliant with the exception of the pump which complies to NSF Part G building regulations Hot water safety All safety and discharge devices supplied as standard wit...

Страница 27: ...ur statutory rights 5 No warranty applies to the filter cartridge life this is effected by the setup varying water quality and personal pattern of usage and as such the combination of these variables...

Страница 28: ...26 Notes...

Страница 29: ...27 Notes...

Страница 30: ...28 Notes...

Страница 31: ...29 Notes...

Страница 32: ...Clarence Street Royal Leamington Spa Warwickshire CV31 2AD England Tel 44 0344 5765597 GEO Email consumer agarangemaster co uk AGA Email customerrelations agarangemaster co uk...

Отзывы: