Due to our policy of continual improvement, we reserve the right to change specifications without prior notice.
Due to the unique filter formulation and technology,
conventional hardness test strips or digital meters cannot
accurately show if the ION media (boiler scale protection
and hardness reduction media) within the filter has been
exhausted.
The only way of judging if the ION media is exhausted and
therefore your filter needs to be replaced is by following the
subsequent steps:
1.
Press and hold the
MENU
and
DOWN SCROLL
button
simultaneously.
2.
You should see a similar information screen to this
example (
Fig. 7.1
).
3.
Take note of the “
WATER USAGE
” value then press the
POWER
button to return from this menu.
4.
Take your GB Clark hardness value and add 2°
(otherwise use the PPM hardness value and add 30PPM).
Now compare this
NEW HIGHER
Clark hardness value against
the table in conjunction with the
WATER USAGE
value.
If the
WATER USAGE
figure is higher than the value
*
REPLACE LITRES
value in the table then filter will require
replacing.
Worked Example:
WATER USAGE
= 0862 litres, your local
water hardness is 11 °Clark, add 2 °Clark, then the ‘
REPLACE
LITRES
’ value in the table for 13 °Clark is 850 litres. In this
example the ‘
WATER USAGE
’ is more than ‘
REPLACE LITRES
’
so the filter requires replacement.
Replacement filters can be obtained by contacting the service
agent number on the sticker on the top of the boiler.
If the filter does not need replacing (for instance you have
installed the product in a soft water supply area), you can
reset the filter reminder beep & indicator bar by pressing and
holding both the up (
) and down (
) buttons together.
IMPORTANT:
Before you reset the filter counter you must
keep a written note of the
WATER USAGE
value for when you
next check your filter. When you come to recheck the
WATER
USAGE
you must add the ‘new’ and ‘previous’
WATER
usage
totals together and use the combined total against the chart.
Whilst you get used to your likely personal filter replacement
schedule, we recommend re-checking filter life frequently to
protect the boiler from scale.
STATUS 2553 0000
SW:H01 OFFSET 0361
WATER LEVEL -2 NORMAL
HEATING - PASS
PCB - PASS
NTC - PASS
FILTER - 6105 HOURS
WATER USAGE - 0862 LITRES
GB °Clark
PPM
*REPLACE LITRES
5
70
1960
6
90
1610
8
107
1415
9
125
1215
10
143
1065
11
161
945
13
179
850
14
196
775
15
214
640
16
232
590
18
250
545
19
268
510
20
286
480
21
304
450
24
339
405
26
375
365
29
411
335
33
464
250
36
518
220
41
589
185
48
679
170
Fig. 7.1