INSTALLATION
Check the appliance is electrically safe and gas sound when you have finished.
Provision of Ventilation
This appliance is not connected to a combustion
products evacuation device. Particular attention shall
be given to the relevant requirements regarding
ventilation.
The room containing the cooker should have an air
supply in accordance with BS 5440 Part 2 : 2000. All
rooms require an openable window or equivalent,
while some rooms require a permanent vent in
addition to the openable window. The cooker should
not be installed in a bedsitting room with volume less
than 20m
3
. If it is installed in a room of volume less
than 5m
3
an air vent of effective area 100cm
2
is
required; if it is installed in a room of volume
between 5m
3
and 10m
3
, an air vent of effective area
50cm
2
is required; while if the volume exceeds 11m
3
,
no air vent is required.
If there are other fuel burning appliances in the same
room, BS 5440 Part 2 : 2000 should be consulted to
determine the requisite air vent requirements.
Location of Cooker
The cooker may be installed in a kitchen/kitchen diner
but NOT in a room containing a bath or shower.
NOTE:
An appliance for use on LPG shall not be
installed in a room or internal space below
ground level. e.g. in a basement.
Conversion
All models are supplied set for use on group H
natural gas. A conversion kit for LP gas is included
with the appliance. See the instructions that are
supplied with the conversion kit. After converting the
appliance please attach the Gas Conversion sticker
over the appropriate area of the data badge, this will
identify the gas type the appliance is now set for.
This appliance is designed for domestic
cooking only. Use for any other purpose
could invalidate any warranty or liability
claim.
You will need the following
equipment to complete the cooker
installation satisfactorily
STABILITY BRACKET
If the cooker is to be supplied with gas through a
flexible hose, a stability bracket or chain must be
fitted.
These are not supplied by with the cooker
but are available at most builders’ merchants.
GAS PRESSURE TESTER
FLEXIBLE GAS HOSE
Must be in accordance with the relevant
standards.
A hose is not supplied by with
the cooker.
Hoses may be purchased at most
builders’ merchants.
MULTIMETER
(for electrical checks)
You will also need the following tools:
1. Electric drill
2. Masonry drill bit (only required if fitting the
cooker on a stone or concrete floor)
3. Rawlplugs (only required if fitting the cooker
on a stone or concrete floor)
4. Steel tape measure
5. Cross head screwdriver
6. Flat head screwdriver
7. Spirit level
8. Pencil
9. Adjustable spanner
10.Screws for fitting stability bracket