38
Technical Data
This cooker is category II
2H3+
It is supplied set for group H natural gas.
A conversion kit from NG to LP gas is included.
INSTALLER: Please leave these instructions with the User.
DATA BADGE LOCATION:
Cooker back, serial number repeater badge below oven door opening.
Country of Destination: GB/IE
Gas
Electric
Natural Gas
20mbar
230V 50Hz
Butane
29mbar
Propane
37mbar
(See appliance data badge for test pressures)
Dimensions
Overall height minimum 898mm
maximum 925mm
Overall width
1100mm See ‘Positioning of Cooker’
Overall depth
648mm
Space for fixing
See ‘Positioning of Cooker’
Minimum space above hotplate
650mm
Connections
Gas
:
Electric
Rp
1
/
2
at rear centre230V 50Hz
Ratings
Natural Gas
L.P. Gas
Injector
Injector
Hotplate
Wok burner
3.65kW internal 80
3.5kW (246g/h)
internal 54
external 129
external 77
Large Burner
3.0kW
134
3.0kW (210g/h)
87
Medium Burners
1.7kW
109
1.7kW (119g/h)
68
Small Burner
1.0kW
75
1.0kW (70g/h)
51
Gas burner inputs based on Gross Calorific Value
Ovens
Left hand Multi-function Oven
Right hand Fan Oven
Fan element
2.5kW
2.5kW
Top element
1.2kW
Browning Element
1.15kW
Bottom element
1.0kW
Maximum total electrical load at 230V
5.1kW*
*approximate total including oven lights, oven fan etc.