OWNER’S MANUAL
31
TTM57mkII
Sensors
Fader Calibration
After cleaning or replacement, the sensors may get moved, affecting the contour. After any fader service,
perform this procedure to re-calibrate the faders and crossfader.
1. Power off the TTM57mkII.
2. Move all faders to the center-most position.
3. Push down both of the Low Kill buttons at the same time.
4. While holding these buttons down, power on the TTM57mkII.
5. Immediately after powering up, the lights will flash one time, indicating a successful calibration. If the
lights flash three times, the sensors may have moved too far or all faders were not properly centered,
and the faders cannot correctly calibrate.
Fader Replacement
You probably won't need to replace a magnetic fader, as cleaning usually solves the problem. If you really
need a spare, they are available for US customers at the Rane Factory Store at
rane.com
. They are also
available through Rane's international distributors, found through
dj.rane.com
. Please order the
Magnetic
Fader V2
. The fader from the original TTM57SL will not work in the TTM57mkII.
Problems?
Contact Rane Corporation customer service at 425-355-6000 or email us at [email protected].
Online help is available at
dj.rane.com
.