Remote Controls
The CP64S supports wired remotes for
Page Assign
,
Zone Level
and
Zone Source
selection. Wire lengths of up to 1000 feet are
possible. A brief list of suitable wire types is provided in the
WIRE TYPES section on the next page.
ZR1 ZONE SOURCE / LEVEL REMOTE
The ZR1 remote provides Zone Level and Source Selection,
allowing local control from inside the Zone. Two ZR1 remotes
may be used (only use
one
in each Zone). If only one of the two
controls is used, you may cover the unused control with one of
the hole plugs provided in the kit. If you require one ZR1 remote
to control both Zones, simply wire the ports in parallel. This
may be done with Program Select only, Level only or both. If
only one of the two controls is wired in parallel, the other is still
available for a second remote.
When paralleling one remote across multiple CP64S’s,
all
three
control pins
must
be wired, including the shields.
Keep the power cable unplugged to the CP64S
until all
connections are made. It is important to ensure that the CP64S
Remote Ports are not subjected to sustained voltages outside the
range of 0 to 5 volts DC or high levels of static. Inputs are pro-
tected, however, caution is the better part of… you know. It is a
good idea to install the wiring, connect it to the remote assem-
blies and then make the final connections at the CP64S. Do
not
short Vr
1
or Vr
2
pins to ground. These pins
are
current limited,
however, excess heat is generated in the 5 volt supply if a short
occurs.
Never subject the Vr
1
or Vr
2
pins to voltages above 5 volts.
ZR1
Zone / Level Remote, side view, and schematic
1
2
3
4
5
S1A
6
7
8
9
10
S1B
2
3
4
1
5
J1A
5 POS TERM
GND
GND
GND
D1
D0
Vc
Vr1
CW
2
1
3
R1
2KRD
VR1 LEVEL REMOTE
Rane provides the
VR1
Volume Remote for
some applications that require a remote level
control without the program selector found in
the ZR1. It contains the same 2k RD taper pot,
and connects as shown in the ZR1 schematic.
With the front panel REMOTE switch, all
selection and level is done either on the front
panel or at the remote; never both locations.
Connecting just a VR1 to the CP64S remote
control terminals will allow level adjustment.
However without a source selector, the unit
will default to source one. If the PRIORITY /
L4 INPUT automatic switching is enabled, then the unit will
select the L4 signal when present and L1 at any other time. Thus
if only a jukebox (P/L4) and other line source (L1) are used, the
remote volume control will work just fine.
REMOTE MOUNTING
The ZR1 and VR1 remote assemblies mount in a standard U.S.
electrical box with a minimum depth of 2.25". Be sure to note
the wire color of each input in order to facilitate correct wiring
to the CP64S. Connect each wire to the Euro connector by fully
inserting it in the correct socket and tightening the screw. Make
sure wires are free of nicks and that the cable jacket is stripped
back sufficiently to allow it to lie in the electrical box with the
remote assembly inserted. Use the flat head #6 screws supplied
with the kit to mount the remote assembly and silk-screened
PROGRAM SELECT
LEVEL
8
2
10
0
4
6
L1
L3
L2
P
4
0
2
6
8
10
LEVEL
Содержание CP 64S
Страница 27: ...This page intentionally left blank Go ahead Doodle ...
Страница 28: ......