15
CP64S
COMMERCIAL PROCESSOR
Parameter
Specification
Limit
Units Conditions/Comments
MIC/LINE PAGING INPUTS
Two mono
All controls duplicated for both inputs
..........Input Type
Euroblock
Balanced; Instrumentation amplifier
..........RFI Filter
Yes
..........Gain range
+30 to +60
2
dB
Continuously adjustable
..........Frequency Response
30 Hz to 40 kHz
+0/-3
dB
Maximum gain
..........Input Referred Noise
-125
1
dBu
Gain: 60 dB, Rs: 150 Ω, BW: 20 kHz
..........CMR
40
min
dB
20 to 20 kHz
..........THD+N
.05
.01
%
Gain: 30 dB, +4 dBu out, 1 kHz, BW: 80 kHz
..........Phantom Power
+15
4%
VDC
Internal switch
..........Mic Input impedance
500
1%
Ω
Each leg to ground
..........Line Pad
30
1
dB
..........Line Input impedance
14.5k
1%
Ω
Each leg to ground. Defeats phantom power
..........Signal Detector Range
off to +4
typ
dBu
Continuously adjustable
..........Signal Detector Attack
.5
typ
msec
Fixed
..........Signal Detector Release
3
typ
sec
Fixed
..........Overload Indicator
+16
1
dBu
4 dB before clipping.
..........Front Panel Zone Assign
Remote, Z1, Z2, Both
Z1 = Zone 1; Z2 = Zone 2
..........Remote Zone Assign
Off, Z1, Z2, Both
Internal pull-up; Active low;
Switch closure to ground or 5 volt TTL logic.
..........Pre/Post Paging assign
Summed with program Pre VCA or Post VCA via Internal switch
..........Page Priority Assign
P1 (Page 1)
NO (none)
P2 (Page 2)
1
dBu
Priority pager overrides non-priority pager only
in assigned zones; Selecting NONE allows the
two pagers to mix.
..........Paging Zone Level Adjust
off to 0
dB
Independent for each Zone
..........Page Remote Selector
11 = Off
10 = Z1 (Zone 1)
01 = Z2 (Zone 2)
00 = Both
1
dBu
Internal pull-up. Active low;
Switch closure to Ground or 5 volt TTL logic.
PROGRAM INPUTS
Four stereo
All controls duplicated for all four inputs
..........Input Type
RCA
Unbalanced
..........Input Level adjust
off to 0
dB
..........Frequency Response
10 Hz to 50 kHz
+0/-3
dB
..........Input impedance
10 k
20%
Ω
.....Priority Program Input
...............Input Detector Range
off to -35
typ
dBu
Internal trim, factory set to -50 dBu
...............Release Time Range
5 to 20
typ
sec
Internal trim, factory set to 12 seconds
...............Attack Time
50
typ
msec
For a 20 dB step; Fixed.
...............Assign
OFF, Z1, Z2 or Both
EXPAND OUTPUTS
All controls duplicated for both zones
..........Number of Expand Outputs Two
Z1 & Z2, both mono
..........Expand Selector
Zone
Program only
Page only
Note: If a Page signal is summed Post-VCA, it
is not present on the Expand Zone output. It is
available for the Expand Page output.
..........Output Type
Balanced
Cross-coupled; Euroblock connector
..........Gain: Zone
12
1
dB
....................Page/Program
6
1
dB
..........Frequency Response
10 Hz to 50 kHz
+0/-3 dB
Specifications