Page Priority Assign

 allows you to select one of the Page 

Inputs as a Priority Page Input. The Priority Pager overrides the 

non-priority Pager in the Zone(s) it is assigned. The non-priority 

Pager may still broadcast in any Zone that the Priority Pager is 

not

 assigned to 

or

 not currently broadcasting in. If a Page Input 

is used for emergencies, set it as the Priority Pager. Set the switch 

to 

P1

 if you wish Page 1 to have priority over Page 2 (the default 

setting). If you wish Page 2 to have priority over Page 1, set the 

switch to 

P2

. If 

NO

 is selected, neither Paging Input has priority 

and both Pagers may be active at the same time. This allows the 

Paging Inputs to mix for applications like karaoke or PA. 

4 5 

The 

Zone 1 Page

 and 

Zone 2 Page

 switches allow you 

to sum Page signals with Program signals “

Pre

” (before) or 

Post

” (after) the VCA. The VCA is used for Zone Level control 

and Limiting. Therefore, if you require the Page Level to be 

controlled 

independent

 of the Program Level, set the switch for 

that Zone to “

Post

.” This is the default setting, and is best for 

emergency paging. If “

Pre

” is selected, Paging signals sum with 

Program signals before the VCA. In this instance both Page 

and Program signal levels 

are

 affected by the front panel ZONE 

LEVEL control. Note the following:

•   Zone Level, EQ and Limiter circuits 

do not

 affect Page signals 

summed Post-VCA.

•   Zone Level, EQ and Limiter circuits 

do 

affect Page signals 

summed Pre-VCA.

•   Page signals are 

not

 available on the Expand Zone output 

when summed Post-VCA.

•   Page signals are 

always

 available for the Expand Page output.

There are two internal controls related to the 

Program Priority

 

detector:

6

 Priority Release Time 

2 sec to 20 sec (trim pot)   

 

    

Default: 12 seconds

7

 Priority Threshold

 

-∞ to -35 dBu (trim pot)   

 

    

Default: -50 dBu

The default settings for the Program Priority detector are chosen 

for most applications. Detector Threshold settings lower than the 

default setting of -50 dBu are prone to false triggering unless the 

source is very quiet. If a source is noisy, you may wish to set the 

threshold higher to prevent false triggering. The default Release 

Time is 12 seconds. You may wish to decrease the Release Time 

if the source is a TV, radio, satellite or other relatively constant 

signal source. If you have a source like a jukebox, with relatively 

long search times, you may wish to extend the Release Time.

There is one internal control related to 

Zone 1

:

8

 Zone 1 Mode

  

Mono/Stereo 

Default: Stereo

CP64S Connections

Do not connect the power cable to the CP64S until all connections 

are made.

All Input and Output connections are made with Euroblock 

connectors except for the RCA Program Inputs. When wiring 

to Euroblocks, a minimum wire gauge of 22 is preferred for 

reliability (maximum 12 guage). If the ground or shield wire 

is left shorter, it acts as a strain relief for the other wires. Cable 

with a flexible jacket is easier to use and less likely to damage the 

connections. Avoid stripping excess insulation. Inspect wires for 

nicks that may lead to wire breakage. Fully insert each wire in 

the appropriate socket and tighten the screw.

Page Input circuits operate balanced or unbalanced. Expand 

and Zone Outputs are driven by cross-coupled line drivers and 

operate balanced or unbalanced. For both Inputs and Outputs, 

wiring is the same. Balanced operation is recommended, and 

necessary when wire lengths are greater than 10 feet (3 meters). 

Balanced wiring is (+) to (+), (–) to (–) and shield to shield.

For unbalanced operation, we recommend using 

two conduc-

tor cable with shield

. The cable is wired to the CP64S the same 

as for balanced operation. At the 

other

 end of the cable, connect 

the (+) wire to signal “hot” and both the (–) 

and

 shield wires to 

ground 

(important.)

If you use 

single conductor cable with shield

, connect the 

shield/gnd wire to both the (–) and shield pins at the CP64S. At 

the 

other

 end of the cable connect the (+) wire to the signal “hot” 

and the shield/gnd wire to ground. When unbalanced wiring is 

used, it is very important for the CP64S and any other unit in 

the system to have good earth or technical grounds. If a unit is 

located more than 10 feet (3 meters) away from the CP64S or 

is of a type that might create grounding problems, use isolation 

transformers with unbalanced cable.

When operating cross-coupled line drivers unbalanced 

(i.e., any 

CP64S Output)

, it is 

essential

 to ground the (–) pin.

The four stereo Program Inputs connect to RCA jacks. These 

Inputs are unbalanced. The same guidelines given above for 

unbalanced operation apply to these Inputs.

Depending on building grounding, an occasional source of 

system hum is powering sources and amplifiers on different elec-

trical circuits. Try connecting everything on the same circuit.

See the RaneNote "Sound System Interconnection" on page 

19 to answer any uncertainties, especially when using unbal-

anced sources.

PRIORITY

ASSIGN

ZONE

ZONE

1

PAGE

+30

+60

1&2

PRIORITY

3

2

1

RANE CORPORATION

OL

Z2 Z1

Z1 Z2

+

+

+

+

D1 D0

Vr Vc

Vr Vc

1

2

DETECT THRESHOLD

REMOTE PAGE

ZONE ASSIGN WIRING

PAGE 2

PAGE 1

LIMITER

WIRING

ZONE 1

ZONE 2

PAGE 1

TRIM

PAGE 2

TRIM

+8

+8

PAGING INPUTS

R

L

R

L

+30

+60

MIC

LINE

–20

+20

–20

+20

REMOTES

OUTPUTS

MIN

MAX

PROGRAM INPUTS

ZONE 2

EXPAND OUT

ZONE 1

EXPAND OUT

ZONE

2

Z2 PGM

Z2 EXPAND Z2 MONO

REMOTE 1

INPUT 1

REMOTE 2

INPUT 2

Z1 RIGHT

Z1 EXPAND

Z1 LEFT

Z2 LEVEL

Z1 PGM

Z1 LEVEL

MIC

LINE

100-240 V

50/60 Hz 12 WATTS

PGM

PGM

PAGE

 off

ALL AUDIO AND 

REMOTES ARE 

CLASS 2 WIRING

CP64S

COMMERCIAL AUDIO

EQUIPMENT 24TJ

R

Содержание CP 64S

Страница 1: ...CP64S COMMERCIAL PROCESSOR INSTALLATION GUIDE 10 0 4 6 10 0 4 6 10 0 4 6 10 0 4 6 2 4 5 6 7 8 9 10 11 13 17 18 19 29 31 Schematics are downloadable at rane com cp64s html 22281 ...

Страница 2: ... the power cord is the AC mains disconnect device and must remain readily operable To completely disconnect this apparatus from the AC mains disconnect the power supply cord plug from the AC receptacle 16 This apparatus shall be connected to a mains socket outlet with a protective earthing connection 17 When permanently connected an all pole mains switch with a contact separation of at least 3 mm ...

Страница 3: ... courant alternatif AC et doit absolument rester accessible Pour déconnecter totalement l appareil du secteur débranchez le câble d alimentation de la prise secteur 16 Cet appareil doit être branché à une prise terre avec protection 17 Quand il est branché de manière permanente un disjoncteur tripolaire normalisé doit être incorporé dans l installation électrique de l immeuble 18 En cas de montage...

Страница 4: ...RMT 1 2 1 2 1 2 ZONE 1 ZONE 2 PAGING ZONE ASSIGN LEVEL L1 P L2 L3 4k 630 1 6k 40 100 250 10k CP64S COMMERCIAL PROCESSOR ACTIVE ACTIVE PAGE 2 PAGE 1 LINE 1 LINE 2 LINE 3 PRIORITY ON OFF SIG OL DUCKER DEPTH PROGRAM SELECT LEVEL L1 P L2 L3 ON OFF SIG OL DUCKER DEPTH PROGRAM SELECT LEVEL PROGRAM INPUT LEVELS ZONE 1 ZONE 2 ZONE 2 4k 630 1 6k 40 100 250 10k ZONE 1 POWER RMT RMT 12 6 6 12 0 10 4 6 10 4 6...

Страница 5: ...R TRIM TRIM DET P1 P2 PAGE 2 DETECT SENS DET Z1 PAGE LEVEL Z2 PAGE LEVEL PRE POST VCA Z1 PRE PAGE Z1 PAGE Z1 POST PAGE Z2 POST PAGE PRE POST VCA Z2 PRE PAGE Z2 PAGE SELECT PROGRAM REMOTE CH 4 CH 1 CH 3 CH 2 LOCAL Z2 Z1 Z2 Z1 LOGIC SELECT CHANNEL Z1 VC AUTO FADE Z2 VC 5 LEVEL RMT LOCAL ZONE 1 ZONE 1 RMT LOCAL RMT LOCAL 5 ZONE 2 LEVEL RMT LOCAL ZONE 2 RMT SEL PAGE DUCKER PRIORITY PAD 30dB PAD 30dB 1...

Страница 6: ...hreshold Zone Assign and Zone Level controls Internally selectable phantom power is provided for each input Each Paging input may be summed Pre or Post Zone Level control to allow setting Paging Level independent of Zone Level An internal Paging Priority switch allows a master pager to override non priority paging in its assigned zones while allowing true dual zone independent paging If no Paging ...

Страница 7: ...CT controls are inactive when RMT is selected Two optional wired ZR1 remotes may be connected to the Remotes port An object smaller in diameter than the switch button is required to engage the recessed RMT switches 9 ZONE SIG and OL indicators show SIGnal present at 20 dBu and OverLoad at 16 dBu 4 dB before clipping respectively Signal indicators are located pre EQ and pre VCA 0 ZONE LEVEL control...

Страница 8: ...e true voltage limiters with a ratio of 15 1 The threshold range is 20 dBu to 20 dBu 6 OUTPUTS feature balanced cross coupled line drivers with a Euroblock connector for each Zone Zone 1 is stereo Zone 2 is mono and both Expand outputs are mono When operating cross coupled line drivers unbalanced it is essential to ground the pin See CP64S Connections on page 10 7 ZONE EXPAND OUT switches assign P...

Страница 9: ...then set the appropriate switch to ON If a Paging Input Mic Line pad switch is set to LINE Phantom Power is automatically defeated 1 3 4 5 8 7 6 2 There are five internal switches related to the two Page Inputs The dot on the circuit board shows the factory default 1 Page 1 Phantom Power 15 VDC Default OFF Controls Phantom Power at the Page 1 connector 2 Page 2 Phantom Power 15 VDC Default OFF Con...

Страница 10: ...uroblock connectors except for the RCA Program Inputs When wiring to Euroblocks a minimum wire gauge of 22 is preferred for reliability maximum 12 guage If the ground or shield wire is left shorter it acts as a strain relief for the other wires Cable with a flexible jacket is easier to use and less likely to damage the connections Avoid stripping excess insulation Inspect wires for nicks that may ...

Страница 11: ...ed in the 5 volt supply if a short occurs Never subject the Vr1 or Vr2 pins to voltages above 5 volts ZR1 Zone Level Remote side view and schematic 1 2 3 4 5 S1A 6 7 8 9 10 S1B 2 3 4 1 5 J1A 5 POS TERM GND GND GND D1 D0 Vc Vr1 CW 2 1 3 R1 2KRD VR1 LEVEL REMOTE Rane provides the VR1 Volume Remote for some applications that require a remote level control without the program selector found in the ZR1...

Страница 12: ...ns in wire type do not greatly affect the performance of the remote controls 22 gauge stranded wire with a flexible jacket is recommended You may use 5 conductor unshielded remote control signal cable for shorter runs less than 200 feet 60 meters or 4 conductor 2 pair shielded remote control signal cable use the shield as the ground return for longer runs 200 to 1000 feet 60 to 300 meters The type...

Страница 13: ... ZONE 2 EXPAND OUT ZONE 1 EXPAND OUT ZONE 2 Z2 PGM Z2 EXPAND Z2 MONO REMOTE 1 INPUT 1 REMOTE 2 INPUT 2 Z1 RIGHT Z1 EXPAND Z1 LEFT Z2 LEVEL Z1 PGM Z1 LEVEL MIC LINE 100 240 V 50 60 Hz 12 WATTS PGM PGM PAGE off ALL AUDIO AND REMOTES ARE CLASS 2 WIRING CP64S COMMERCIAL AUDIO EQUIPMENT 24TJ R Make sure the power is disconnected Control Presets Page settings repeat for second page input Input Pad rear ...

Страница 14: ...same level as the first Page source it should be close If not use the Page Trim control of the second Page source to adjust its gain to match If you change the gain of the second Page source substantially be sure to reset the Page Detect Threshold 8 Set the Ducker switch to ON With an active Program source playing speak into the Page Mic and adjust the Ducker Depth as required Repeat for both Zone...

Страница 15: ... Post VCA via Internal switch Page Priority Assign P1 Page 1 NO none P2 Page 2 1 dBu Priority pager overrides non priority pager only in assigned zones Selecting NONE allows the two pagers to mix Paging Zone Level Adjust off to 0 dB Independent for each Zone Page Remote Selector 11 Off 10 Z1 Zone 1 01 Z2 Zone 2 00 Both 1 dBu Internal pull up Active low Switch closure to Ground or 5 volt TTL logic ...

Страница 16: ...sly adjustable Limiter Threshold Range 20 to 20 typ dB Continuously adjustable Attack Time 20 typ msec For a 10 dB step Fixed Release Time 250 typ msec For a 10 dB step Fixed Ratio 15 1 typ Soft knee PROGRAM SELECTION Local Front Panel L1 L2 L3 or P priority Independent for each Zone Zone RMT Selector 11 L1 10 L2 00 L3 01 P Internal pull up Active low Switch closure to ground or 5 volt TTL Gray Co...

Страница 17: ...N WIRING PAGE 2 PAGE 1 LIMITER WIRING ZONE 1 ZONE 2 PAGE 1 TRIM PAGE 2 TRIM 8 8 PAGING INPUTS R L R L 30 60 MIC LINE 20 20 20 20 REMOTES OUTPUTS MIN MAX PROGRAM INPUTS ZONE 2 EXPAND OUT ZONE 1 EXPAND OUT ZONE 2 Z2 PGM Z2 EXPAND Z2 MONO REMOTE 1 INPUT 1 REMOTE 2 INPUT 2 Z1 RIGHT Z1 EXPAND Z1 LEFT Z2 LEVEL Z1 PGM Z1 LEVEL MIC LINE 100 240 V 50 60 Hz 12 WATTS PGM PGM PAGE off ALL AUDIO AND REMOTES AR...

Страница 18: ...IRING PAGE 2 PAGE 1 LIMITER WIRING ZONE 1 ZONE 2 PAGE 1 TRIM PAGE 2 TRIM 8 8 PAGING INPUTS R L R L 30 60 MIC LINE 20 20 20 20 REMOTES OUTPUTS MIN MAX PROGRAM INPUTS ZONE 2 EXPAND OUT ZONE 1 EXPAND OUT ZONE 2 Z2 PGM Z2 EXPAND Z2 MONO REMOTE 1 INPUT 1 REMOTE 2 INPUT 2 Z1 RIGHT Z1 EXPAND Z1 LEFT Z2 LEVEL Z1 PGM Z1 LEVEL MIC LINE 100 240 V 50 60 Hz 12 WATTS PGM PGM PAGE off ALL AUDIO AND REMOTES ARE C...

Страница 19: ...connections Grounding and EMC practices Shields of connectors in audio equipment containing active circuitry Rane s policy is to accommodate rather than dictate However this document contains suggestions for external wiring changes that should ideally only be implemented by trained technical personnel Safety regulations require that all original grounding means provided from the factory be left in...

Страница 20: ...rconnect is not compat ible with unbalanced The small physical nature and short cable runs of completely unbalanced systems home audio also contain these ground loop noise currents However the currents in unbalanced systems never get large enough to affect the audio to the point where it is a nuisance Mixing balanced and unbalanced equipment however is an entirely different story since balanced an...

Страница 21: ...ACTICE RECOMMENDED PRACTICE OPTIONAL CASE 1 2 3 3 1 2 CHASSIS GROUND SIGNAL GROUND CHASSIS GROUND CHASSIS GROUND The Next Best Right Way To Do It The quickest quietest and most foolproof method to con nect balanced and unbalanced is to transformer isolate all unbalanced connections See Figure 2 Many manufacturers provide several tools for this task including Rane Consult your audio dealer to explo...

Страница 22: ...rounded and therefore immune to ground loop hums and buzzes Ground lifts are simply another Band Aid to try in case of grounding problems It is true that an entire system of properly grounded equipment without ground lift switches is guaranteed yes guaranteed to be hum free The problem is most equipment is not both internally and externally AC system wise grounded properly Most units with ground l...

Страница 23: ...o guarantee that a hum free intercon nect can be achieved nor is there a definite scheme that will assure noise free operation in all configurations References 1 Neil A Muncy Noise Susceptibility in Analog and Digi tal Signal Processing Systems presented at the 97th AES Convention of Audio Engineering Society in San Fran cisco CA Nov 1994 2 Grounding Shielding and Interconnections in Analog Digita...

Страница 24: ... 20 24 24 19 18 17 B B B B A A A A A A FEMALE BALANCED XLR NOT A TRANSFORMER NOR A CROSS COUPLED OUTPUT STAGE FEMALE BALANCED XLR EITHER A TRANSFORMER OR A CROSS COUPLED OUTPUT STAGE BALANCED TRS NOT A TRANSFORMER NOR A CROSS COUPLED OUTPUT STAGE BALANCED TRS EITHER A TRANSFORMER OR A CROSS COUPLED OUTPUT STAGE FLOATING UNBALANCED TRS TIP RING SLEEVE SLEEVE IN UNIT NC OR 3 5 mm UNBALANCED TS TIP S...

Страница 25: ... RED SHIELD RED SHIELD SHIELD RED RED BLACK N C N C N C RED BLACK RED SHIELD N C BLACK RED BLACK RED 3 NC 2 RED 1 SHIELD 2 RED 1 SHIELD 3 BLACK 2 RED 1 NC 3 BLACK 2 RED 1 NC 3 BLACK 2 RED 1 SHIELD SHIELD FEMALE FEMALE FEMALE RED SHIELD RED BLACK SHIELD SHIELD RED BLACK RED BLACK BLACK RED RED SHIELD RED SHIELD RED SHIELD RED SHIELD RED BLACK 2 CONDUCTOR SHIELDED CABLE 2 CONDUCTOR SHIELDED CABLE 2 ...

Страница 26: ...D 3 BLACK 2 RED 1 SHIELD 3 BLACK 2 RED 1 SHIELD SHIELD BLACK SHIELD RED BLACK SHIELD RED BLACK RED SHIELD SHIELD BLACK RED SHIELD BLACK RED SHIELD BLACK RED SHIELD BLACK RED SHIELD BLACK RED SHIELD RED SHIELD RED SHIELD RED SHIELD RED BLACK RED N C N C BLACK RED BLACK RED BLACK RED RED SHIELD RED SHIELD RED SHIELD RED 24 S BLACK T RED CROSS COUPLED OUTPUT ONLY CONNECT BLACK TO SHIELD AT THIS END A...

Страница 27: ...This page intentionally left blank Go ahead Doodle ...

Страница 28: ......

Страница 29: ...UNTRY AGAINST DEFECTS IN MATERIAL OR WORKMANSHIP THE SPECIFIC PERIOD OF THIS LIMITED WARRANTY SHALL BE THAT WHICH IS DESCRIBED TO THE ORIGINAL RETAIL PURCHASER BY THE AUTHORIZED RANE DEALER OR DISTRIBUTOR AT THE TIME OF PURCHASE Rane Corporation does not however warrant its products against any and all defects 1 arising out of materials or workmanship not provided or furnished by Rane or 2 resulti...

Страница 30: ...E THE UNIT WAS PURCHASED OR if product was purchased in the U S AT THE RANE FACTORY IN THE U S If the product is being sent to Rane for repair please call the factory for a Return Authorization number We recommend advance notice be given to the repair facility to avoid possible needless shipment in case the problem can be solved over the phone UNAUTHORIZED SERVICE PERFORMED ON ANY RANE PRODUCT WIL...

Страница 31: ...ssional electronic A V apparatus immunity EN50581 2012 Technical documentation for RoHS assessment of electronic products Additional Information Environment E2 CE mark first affixed in 2007 In order for the customer to maintain compliance with these regulations high quality shielded cable must be used for interconnection to other equipment No changes or modification of the equipment other than tha...

Страница 32: ...ZONE 1 ZONE 2 PAGE 1 TRIM PAGE 2 TRIM 8 8 PAGING INPUTS R L R L 30 60 MIC LINE 20 20 20 20 REMOTES OUTPUTS MIN MAX PROGRAM INPUTS ZONE 2 EXPAND OUT ZONE 1 EXPAND OUT ZONE 2 Z2 PGM Z2 EXPAND Z2 MONO REMOTE 1 INPUT 1 REMOTE 2 INPUT 2 Z1 RIGHT Z1 EXPAND Z1 LEFT Z2 LEVEL Z1 PGM Z1 LEVEL MIC LINE 100 240 V 50 60 Hz 12 WATTS PGM PGM PAGE off ALL AUDIO AND REMOTES ARE CLASS 2 WIRING CP64S COMMERCIAL AUDI...

Отзывы: