Remote Control
R&S
®
ESR
738
User Manual 1175.7068.02 ─ 12
CALCulate<n>:LIMit<k>:ACPower:ALTernate<Channel>[:RELative]:STATe
CALCulate<n>:LIMit<k>:ACPower:ALTernate<Channel>:RESult?
....................................... 744
CALCulate<n>:LIMit<k>:ACPower[:STATe]
....................................................................... 745
CALCulate<n>:LIMit<k>:ACPower:ACHannel:ABSolute
<LowerLimit>,
<UpperLimit>
This command defines the absolute limit value for the lower/upper adjacent channel
during adjacent-channel power measurement (Adjacent Channel Power).
Note that the absolute limit value has no effect on the limit check as soon as it is below
the relative limit value defined with
CALCulate<n>:LIMit<k>:ACPower:
. This mechanism allows automatic checking of the absolute
basic values of adjacent-channel power as defined in mobile radio standards.
Suffix:
<n>
.
Selects the measurement window.
<k>
irrelevant
Parameters:
<LowerLimit>,
<UpperLimit>
first value: -200DBM to 200DBM; limit for the lower and the
upper adjacent channel
*RST:
-200DBM
Example:
CALC:LIM:ACP:ACH:ABS -35DBM, -35DBM
Sets the absolute limit value for the power in the lower and
upper adjacent channel to -35 dBm.
CALCulate<n>:LIMit<k>:ACPower:ACHannel:ABSolute:STATe
<State>
This command activates the limit check for the adjacent channel when adjacent-chan-
nel power measurement (Adjacent Channel Power) is performed. Before the com-
mand, the limit check for the channel/adjacent-channel measurement must be globally
switched on using
CALCulate<n>:LIMit<k>:ACPower[:STATe]
The result can be queried with
CALCulate<n>:LIMit<k>:ACPower:ACHannel:
. It should be noted that a complete measurement must be performed between
switching on the limit check and the result query, since otherwise no correct results are
available.
Suffix:
<n>
.
Selects the measurement window.
<k>
irrelevant
Parameters:
<State>
ON | OFF
*RST:
OFF
Remote Commands in Spectrum Analyzer Mode