to ensure that a relay is not active beyond the scheduled time, even if base station
cannot reach the node at that time.
NOTE: RL200 relay expansion units are supported as of firmware 281. Simply specify
relay numbers 4 onwards, and the RS210 will attempt to access RL200(s) on port 6. As
normal with RL200, the first RL200 must be ID 20, the next 21 etc. See service note on
RL200 for more details.
NOTE: The multiple relay syntax is support from firmware version 281 onwards.
Example:
1984>relay 1 1
Relay 1 -> 1 (50 ms)
1984>relay 1
Relay 1: 1
Turn-off in 21597 secs (2009-10-09 18:18:44)
1984>relay 1 0
Relay 1 -> 0 (50 ms)
1984>relay 1 1 60
Relay 1 -> 1 (50 ms)
1984>relay 1
Relay 1: 1
Turn-off in 3597 secs (2009-10-09 13:19:02)
SENSE
Syntax
:
sense
sense
<portno>
Description
:
Causes an immediate sensing of attached sensors, according to configuration.
The
sense
syntax forces immediate sensing of all ports.
The
sense
<portno> syntax on forces sensing on the specified port.
The result of the sensing will not be shown in the shell explicitly, but will show in
subsequent
vdata
command results and be reported to the server like any other
sensing event.
SERIAL
Syntax
:
serial
Description
:
Prints the RS210 node's hardware serial number.