Using
config port
<portno> displays only a specific port's setting.
Using
config sense
forces all current configurations to be reported back to server for
viewing in Node Configuration page.
The following basic settings are available:
Parameter
Description
rsuid
ID number of this unit
base
Base ID number of the base station to which this node should
respond.
meshtype
Controls which type of 802.15 radio is used. Must be set to
match the installed radio type. Options are:
Value
Radio Type
24
2.4GHz global 802.15
900
900Mhz U.S. Unlicensed
msgmode
Messaging mode. If values > 0, the unit will do message
queue processing when synchronizing messages from server
and with RS210 nodes. Normally always on.
defontime
Maximum time a relay should be open if no off-time was
specified in relay open command. This setting provided a
back-stop for open-ended relay activations. The default is
3600 (6 hours).
meshid
PAN id of 802.15. Normally 3332 (hex). Must match same
setting on base station.
meshch
Radio channel used for communication. Must match same
setting on base station.
meshsm
Mesh sleep mode. Normally 4. A value of 0 will turn of sleep.
meshsp
Sleep period setting for the mesh network. Milliseconds in
10ms steps. Must match same setting on base station.
meshst
Time before sleep setting for the mesh network. In
milliseconds. Must match same setting on base station.
meshdp
Sleep period setting for mesh network. Milliseconds in 10ms
steps. Must match same setting on base station.
chrgon
Lower limit voltage setting for charger turn on. Millivolt in 10
mv steps. For example 1070 = 10.70 V.
chrgoff
Upper limit voltage setting for charger turn off. Millivolt in 10
mv steps. For example 1200 = 12.0 V.
c
onfig port
and
config ports
will generate a table format output of settings for the
indicated port(s).
For explanation of
config ports
parameters, please see
configset
command.
18 © Ranch Systems LLC, 2005-2011. All Rights Reserved. Reproduction without permission from Ranch Systems is prohibited.