OPERATION

Theory of Operation

 

When power is applied, fresh air is taken in through air filters and compressed by the pump pistons.  The compressed air is very warm 

and is cooled for use by the heat exchanger and fan.  Air is then delivered to coalescing filter to remove most of the moisture.  The coalesc-
ing filter is equipped with a automatic draining feature that allows the draining of the excess moisture.  The cool air enters the desiccant style 
dryer assembly to complete the moisture removal by removing 99.7% of the water vapor from the air.  Air is directed into the dryer cartridges, 
from one to the other, by electronically controlled solenoid valves.  The timing for the solenoid valves is varied between models and provided 
by the C1 Control.    While the air is moving through one cartridge, the desiccant in the other cartridge is being dried by air directed through an 
orifice in the outlet shuttle valve.  This valve cycle will be noticeable by a short burst of air from the purge valves.  When the air has left the dryer 
assembly it goes through a particulate filter to remove any remaining particulates from the air.  It is then collected in the tank where a pressure 
gauge displays the tank air pressure.   The tank pressure is monitored by a pressure transducer in the C1 Control, which runs the motors on 
demand.  Pressure is factory set to start the compressor at 80 psi and shut off at 100 psi.  

Getting Started

CustomAir

by RAMVAC

 

1000 series compressor is easy to operate and 

maintain.

1.  Verify the compressor is plugged into a dedicated circuit with an
  appropriate electrical outlet.
2.  Verify the compressor is properly connected to the
  facility plumbing and fresh air source.
3.  Verify the outlet valve is closed.
4.  Vent pressure gauge
  a.  Turn yellow tab on top of gauge from closed to open to vent.
5.  Push and hold the power button on the C1 Control for
  approximately 5 seconds to start.  
 

Note:  The power light will go off when the button is held.

6.  Test for leaks.  See 

“Testing Compressor for Leaks”

7.  Turn the shut off valve to open.
8.  The compressor installation is complete.

WARNING:  

DO NOT

 direct air flow toward the body.

WARNING:  

Always

 

turn off compressor and  remove

 

 

  power plug from outlet when servicing.

CAUTION:   

DO NOT 

attempt to 

operate the compressor at

 

 

  ambient temperature below 0º C / 35º F or

 

 

  above 40º C / 104º F. 

 

 

 

 

 

 

CustomAir

®

by RAMVAC®

User Guide

Содержание CustomAir 1000 Series

Страница 1: ...ssors to be operated simultaneously in larger clinics CustomAir compressors are designed using trouble free solid state transducers in lieu of mechanical pressure switches to ensure dependability and...

Страница 2: ...b A w sound cover CFM output at peak airflow SCFM at 100 psi Pump up cycle time sec from 80 100 psi Tank size in gallons Filter Dryer Duty Dryer Dew Point Total HP 1022 2 3 100 208 253 5 1 136 24 x 20...

Страница 3: ...Dental Compressed Air System USER GUIDE Installation and Maintenance Manual For 1000 Series with C1 Control...

Страница 4: ...nal invitation to visit our manufacturing facility in the beautiful Black Hills of South Dakota Matt Olson General Manager RAMVAC Dental Products Inc 800 5 RAMVAC 800 572 6822 Safety and Regulatory In...

Страница 5: ...e Page 8 Filter Maintenance Page 9 Inspecting Dryer Page 10 Testing Safety Valves Page 10 Testing Compressor for Leaks Page 10 Speci cations Page 11 Troubleshoooting Page 12 Warranty Inside back cover...

Страница 6: ...ly contact the freight carrier and supplier 3 Remove lag screws holding the compressor to shipping pallet 4 Verify additional parts shipped with the compressor a Additional parts shipped with all comp...

Страница 7: ...ctrical outlets Electrical cicuit is a dedicated 20 amp circuit C1 Control and Motor Control Box for the 1029T compressor use a 20 amp time delay fuse See Specifications for more electrical informatio...

Страница 8: ...Filter Coalescing Filter Heat Exchanger and Fan Desiccant Dryer Cartridge Pressure Gauge Safety valve Safety Valve Model 1025D is pictured Other models have identical features with the exception of m...

Страница 9: ...particulate lter to remove any remaining particulates from the air It is then collected in the tank where a pressure gauge displays the tank air pressure The tank pressure is monitored by a pressure...

Страница 10: ...1 Turns motors off at 100 psi 2 Turns motors on at 80 psi 2nd motor will start with a 1 second delay Provides a 24VAC low voltage signal to the remote panel Accepts the remote switch input Controls th...

Страница 11: ...rminals Toggle Switch or other non illuminated switch option Vac Switch Vac Light Common F 24 VAC G 24 VAC H AC Common Illuminated Remote Switch C1 Controller Terminals Note Maximum wire length for lo...

Страница 12: ...commended levels High temperatures will shorten the life of the air compressor Follow the recommended preventative maintenance schedule Preventive Maintenance Schedule This is a recommended schedule f...

Страница 13: ...nd remove 5 Remove lter by turning completely out 6 Install new 5 micron lter 7 Position lter bowl push up slightly and turn into place 8 Plug power cord into outlet 9 Return compressor to service Rep...

Страница 14: ...e compressor is still running pull ring on safety valve Note A loud burst of escaping air will be heard when air is released from the safety valve 3 If no air comes out of safety valve the valve is de...

Страница 15: ...8 FRN 25 UNIT POWER CONSUMPTION 5 1 amps 12 0 amps 5 9 amps 8 4 amps 9 5 amps 15 4 amps UNIT DIMENSIONS w x d x h 24 x 20 5 x 28 24 x 20 5 x 26 5 24 x 20 5 x 26 5 24 x 20 5 x 26 5 27 x 22 x 36 WEIGHT...

Страница 16: ...s 4 Dryer malfunction 5 Valves sticking 1 See Test Compressor for Leaks 2 Test facility air lines for leaks 3 Replace intake lters 4 Contact RAMVAC 5 Contact RAMVAC Compressor gets too hot 1 Ambient t...

Страница 17: ...acuum System 2 Years from date of installation RAMVAC Vacuum Pumps only 10 Years from date of installation RAMVAC OWL 2 Years from date of installation CustomAir by RAMVAC 6 Years 4200 hours from date...

Страница 18: ...Brand of the The Integrated Supplier PHONE 866 DTE INFO www dentalez com SOF_7 5 1 07 04 Effective date 28 Sep 07 2007 RAMVAC Dental Products All rights reserved No part of this publication may be co...

Отзывы: