background image

 

YOUR SAFETY AND THE SAFETY OF OTHERS ARE VERY 

IMPORTATNT.

 

 

BEFORE  USE,  PLEASE  READ  AND  FOLLOW  ALL  SAFETY  RULES  AND  OPERATING 

INSTRUCTIONS. AND SAVE FOR LOCAL GAS AND ELECTRICAL INSPECTOR’S USE. 

 

WARNING: 

If  the  information  in  this  manual  is  not  followed  exactly,  a  fire  or  explosion  may  result 

causing property damage, personal injury or death. 

 

Do not store or use gasoline or other flammable vapors and liquids in the vicinity of this or any other 

appliance.

 

 

WHAT TO DO IF YOU SMELL GAS:

 

-

 

Do not try to light any appliance.   

-

 

Do not touch any electrical switch. 

-

 

Do not use any phone in your building. 

 

Immediately call your gas supplier from a neighbor’s phone. Follow the gas supplier’s instructions. 

 

If you cannot reach your gas supplier, call the fire department.   

 

Installation and service must be performed by a qualified installer, service agency or the gas supplier.

 

WARNING:

 Gas leaks cannot always be detected by smell. 

Gas suppliers recommend that you use a gas detector approved by UL or CSA. 

If a gas leak is detected, follow the “What to do if smell gas” instructions above. 

 

IMPORTANT

:  This  is  a  gas  unit  that  requires  professional  licensed  technician  to  install  per  city/state 

safety code. Gas leakage test must be exercised prior to turning on the gas supply. 

 

IMPORTANT SAFETY INSTRUCTIONS

 

WARNING: 

To  reduce  the  risk  of  fire,  electrical  shock,  injury  to  persons,  or  damage  when  using 

cooktop, follow basic precautions, including the following:

 

 

WARNING: 

NEVER use this appliance as a space heater to heat or warm the room. Doing so may 

result in carbon monoxide poisoning and overheating of the cooktop.

 

 

CAUTION: 

Do  not  store  items  of  interest  to  children  in  cabinets  above  the  cooktop  –  children 

climbing on the cooktop to reach items could be seriously injured.     

Содержание GC2-37P

Страница 1: ...1 User Guide Ramblewood Green Gas Cooktop GC2 37P GC2 37N www ramblewoodgreen com sales ramblewoodhk com 1 888 880 8351...

Страница 2: ...ervice must be performed by a qualified installer service agency or the gas supplier WARNING Gas leaks cannot always be detected by smell Gas suppliers recommend that you use a gas detector approved b...

Страница 3: ...it does not extend beyond the edge of the cooking utensil IMPORTANT This appliance is designed and manufactured solely for the cooking of domestic household food and is not suitable for any commercia...

Страница 4: ...ease use the Cutting size board cardboard packed in the box to outline cut hole in counter top Clearance between the underneath of unit and any surface below it should be at least 1 inch 30mm If there...

Страница 5: ...EN CABINET WITH DOOR Fig 2 It is recommended that a 30 mm clearance be left between the cooker top and the fixture surface Fig 2 Note The adjacent furniture and all materials used in installation must...

Страница 6: ...ate kitchen furniture are particularly prone to heat damage or discoloration at temperatures below 85 C DISCHARGING PRODUCTS OF COMBUSTION Extractor hoods connected directly to the outside should be p...

Страница 7: ...d in fig 5 Slot the cooktop into the unit and position Position the cooktop in the recess and secure by means of the brackets as shown in fig 6 for 3 or 4 cm thick work top BUILT IN DIMENSION MODEL CU...

Страница 8: ...10 of Water Column 2490 Pa 4 Your NG cooktop is designed to operate at pressure 5 Make sure you are supplying your cooktop with the type of gas for which it s designed This cooktop is convertible for...

Страница 9: ...s pressure is different than that prescribed a pressure regulator must be installed at the source in compliance with national standards government the use of piped gas regulators To complete the conve...

Страница 10: ...the cooktop Install male 1 2 flare union adapter to the 1 2 NPT internal thread at inlet of regulator Use a backup wrench on the regulator fitting to avoid damage When all connections have been made m...

Страница 11: ...installation or replacement Only use a DC 1 5 Volt battery Check for correct polarity label to the side of the battery compartment the electronic ignition is used Important notes Remove the battery i...

Страница 12: ...y necessary that it be a UL listed 3 wire grounding type appliance extension cord and that the current carrying rotting of the cord in amperes be equivalent to or greater than the branch circuit ratin...

Страница 13: ...a CAUTION Attaching the adapter ground terminal to the wall receptacle cover screw does not ground the appliance unless the cover screw is metal not insulated and the wall receptacle is grounded throu...

Страница 14: ...range is not being used set the gas knobs to their OFF positions and also close the gas shut off valve placed on the main gas supply line LIGHTING GAS BURNERS Any film or stickers on the cooktop surf...

Страница 15: ...table A smaller diameter pot or pan placed on a larger burner does not necessarily mean that the boiling conditions are reach quicker Table of recommended pans Burner Pan diameter in cm Auxiliary Sem...

Страница 16: ...tly repositioned Also check the electrode S Thermocouple are clean to ensure trouble free sparking Stainless steel can be stained if it s in contact with highly calcareous water or aggressive detergen...

Страница 17: ...ring burner must be correctly positioned seen fig 7 the burner rib must be entering in their ligament as shown by the arrow The burner correctly positioned must not be able to rotate fig 8 Then positi...

Страница 18: ...does not stay lit on the model with the safety device Check to make sure that You press the knob all the way in and keep the knob pressed long enough to activate the safety device Please insure the fl...

Страница 19: ...t near the cooking surface Tile minimum has been adjusted correctly see the section entitled Minimum Regulation The cookware is not stable Check to make sure that The bottom of the cookware is perfect...

Отзывы: