21
RAK LoRaWAN Industrial Gateway Configuration Guide
Figure 19 |
Device Configuration parameters
Configuration
Here you can edit device parameters as follows:
Name
– does not need to match the EUI, batch loading results in a match by default.
Class
– both Class A and Class C devices are supported.
Join Mode
– both OTAA and ABP are supported.
Application Key
– note those can be different per device, however devices will still be
grouped by application name.
Enable Frame-Counter Validation
– with this feature turned on, frames that have a counter
number smaller or equal than current counter value.
Disable Application-EUI Validation
– if this slider is on, the Application EUI will not be
checked for validity, the device will join based only on the Application Key and an
Application EUI will be generated.
Activation
Once you have properly configure the parameters of the device mentioned above you
should see the data in the following picture (Activation tab):
Figure 20 |
Device Activation