Devices
If you want to manually add a device to your application, you can do this one by one by
entering their EUIs in the field pressing the “Add” button. Another option is to use the Batch
Add function.
Batch add devices
You need to fill in the following parameters: Start EUI, Step, Count, and Application Key.
The step is a decimal value that represents by how much the value of the EUI will be
increased with each consecutive device. This will be done starting from the least significant
bit.
The count is the maximum number of devices to be added. Note that if your step is anything
different than 1 you will essentially add less devices than the Step value. Basically you will
end up with a number of devices that is the Integer Division of the Count by the Step. For
example if your Step is 3 and your Count is 10 you will end up with 3 Devices.
The Application Key is an AES-128 value, which is common for all devices under a given
application.
Note: When Batch Adding devices they are all configured in Class A, OTAA mode, with
Frame counter validation enabled.
Additionally you can Export/Import the device list in
CSV
format.
Application Configuration
Here resides the data you already entered when creating the Application. You can adjust it
as needed.
Adding and configuring a device
Below is in depth explanation of the data available per device. You can enter this section by
either inputting a valid EUI and pressing the
Add
button, or pressing the
Edit
button for an
existing device:
Figure 18 |
Device Configuration