MANUAL - INSTALLATION
Pipe connections, ventilation
The property's gray water drainage pipe is connected to the HS Bio inlet
(D110 mm). HS Bio's outgoing connection is D110 mm. The water leaving
the unit is passed through the sampling well to the open ditch or through
the infiltration well to the ground.
If the property has drainage ventilation (1) on the roof of the building, the
ventilation will be through it, unless a pipe for ventilation in the incoming
drainage pipe (2) is connected to the surface.
Incoming ventilation for the HS Bio system is also required, from the end of
the pipeline (to open ditches) or from an infiltration well (3).