180-degree shift. Disable this function and set the Rx data phase positive: the Rx data
phase will be 0 degree; disable this function and set the Rx data phase negative: the Rx
data phase will be 180 degree; enable this function and set the Rx data phase positive:
the Rx data phase will be 90 degree.
10.14. Ethernet user-board set menu
This section will explain how to configure Ethernet data user-board.
10.14.1.
Sub-Board Slot Number
In Ethernet user-board set menu press number key 1 to configure the number of
occupied channels:
User Board Slot Number=8(Can Set)
Input Slot Number(0-31):
The first row displays present configuration value and the second row is for your new
configuration.
If you do not set occupied channel number in the second row and just press ENTER, the
old configuration will be reserved. If you set the occupied channel number (the entering
must within the range of 0-31) and press ENTER, the new configuration will be effective.
BackSpace key is available to modify.
The rule of configuring channels is the same as that of V35, please refer to the relative
section of V35 user-board set.
10.14.2. Channel
Select
In Ethernet user board set menu press number key 2 to select data channel:
Data Channel Select: Main Channel
In this status use
→
key to change the configured value: Main channel or Single channel;
Press ENTER to confirm configuration, press E key to finish configuration, and ESC to
cancel configuration.
10.14.3.
Buffer Size Set
In Ethernet user board set menu press number key 3 to set the buffer size:
Buffer Size Set:>256Kbps
In this status use
→
key to change the configured value: >=2Mbps, >1Mbps, >512Kbps,
>256Kbps; Press ENTER to confirm configuration, press E key to finish configuration,
and ESC to cancel configuration.