7. Function & Application
7.1. Function and application explanation of RC3000:
7.1.1. Factory default configuration
There is only hardware version of a new RC3000 and without any cross configuration.
7.1.2. Start
self-check
RC3000 will check all configurations when powered on, including: system configuration
information, cross connect configuration information, line-board information and
user-board information. Meanwhile all LEDs will flick and buzzer will buzz, otherwise
there is error of some parts of device.
7.1.3. System automatic configuration in factory default status
RC3000 will configure itself according to hardware:
Configuration information not related to line-board:
a. Device ID: not configured
b. Baud rate: not configured
c. Alarm shield: not shield any alarm.
d. CRC check: disable.
e. E1 mode: PCM30.
f. Alarm sound: enable
g. Assistant network management channel: 0 time slot.
h. Clock switch mode: auto.
Configuration information related to line-board:
a. Number of E1 interface:
RC3000-OPT: first and second E1 interfaces are used.
RC3000-2E1: first and second E1 interfaces are used.
RC3000-2E1 (ADM): first and second E1 interfaces are used.
RC3000-4E1: first E1 is used.
b. Network management topolosy direction:
RC3000-OPT: dual-E1 direction.