background image

 

Rainwater

 

harvesting

 

system

 

installation;

 

outdoors

 

 

QUICK

 

START

 

Systems

 

with

 

leaf

 

filter

 

in

 

the

 

turret

 

of

 

the

 

underground

 

tank

 

and

 

submersible

 

pressure

sensitive

 

pump,

 

product

 

ID

 

numbers

 

ending

 

GUK1,

 

DUK2,

 

DUK3,

 

DUK4

 

or

 

DUK5

 

1.

 

Read

 

in

 

advance

 

and

 

follow

 

the

 

installation

 

instructions

 

provided

 

with

 

the

 

system:

 

your

 

guarantee

 

is

 

affected

 

if

 

you

 

do

 

not

 

install

 

correctly.

 

2.

 

Tank

:

 

if

 

the

 

water

 

table

 

is

 

within

 

a

 

metre

 

of

 

the

 

surface

 

of

 

the

 

ground

 

you

 

should

 

not

 

install

 

this

 

style

 

of

 

tank

 

but

 

look

 

to

 

using

 

a

 

shallow

 

dig

 

tank

 

or

 

in

 

extreme

 

cases

 

where

 

the

 

water

 

table

 

is

 

very

 

high

 

a

 

Rondus

 

tank

 

would

 

be

 

most

 

suitable.

 

Otherwise

 

backfill

 

the

 

tank

 

to

 

the

 

shoulder

 

with

 

pea

 

shingle

 

(top

 

soil

 

round

 

the

 

turret),

 

making

 

sure

 

that

 

the

 

manufacturers

 

guidelines

 

are

 

followed.

 

3.

 

Dirt

 

in

 

tank

:

 

Do

 

not

 

install

 

or

 

start

 

the

 

pump

 

before

 

all

 

grit

 

(building

 

rubble)

 

and

 

plastic

 

swarf

 

are

 

removed

 

from

 

the

 

bottom

 

of

 

the

 

tank

 

with

 

a

 

separate

 

dirty

 

water

 

pump

 

4.

 

Pump

 

input

:

 

The

 

pump

 

is

 

supplied

 

with

 

a

 

cartridge

 

filter

 

and

 

1

 

inch

 

strainer

 

pre

fitted

 

onto

 

the

 

input

 

of

 

this

 

pump.

 

Do

 

not

 

remove

 

these

 

as

 

this

 

could

 

invalidate

 

your

 

warranty.

 

5.

 

Pump

 

priming

:

 

it

 

is

 

essential

 

that

 

the

 

pump

 

is

 

primed

 

by

 

removing

 

the

 

half

 

inch

 

black

 

cap

 

and

 

pouring

 

approximately

 

5

 

litres

 

of

 

water

 

into

 

the

 

pump

 

through

 

a

 

funnel;

 

failing

 

to

 

do

 

this

 

will

 

cause

 

the

 

pump

 

to

 

burn

 

itself

 

out

 

even

 

if

 

submerged

 

and

 

invalidate

 

your

 

warranty.

 

6.

 

Pump

 

connections

:

 

output

 

pipe

 

(usually

 

supplied

 

and

 

25mm

 

HDPE)

 

runs

 

out

 

of

 

the

 

top

 

of

 

the

 

pump

 

and

 

is

 

cut

 

to

 

length

 

to

 

run

 

straight

 

upwards

 

to

 

a

 

right

 

angle

 

connector

 

(Supplied)

 

from

 

which

 

the

 

pipe

 

runs

 

in

 

to

 

the

 

house

 

through

 

the

 

4

 

inch

 

service

 

pipe.

 

This

 

right

 

angle

 

connector

 

must

 

be

 

within

 

30cms

 

of

 

the

 

surface

 

of

 

the

 

ground

 

(even

 

if

 

extension

 

sleeves

 

are

 

fitted)

 

so

 

that

 

it

 

can

 

be

 

undone

 

in

 

the

 

future

 

for

 

removal

 

of

 

the

 

pump.

  

Service

 

pipe

 

 

Cord

 

from

 

pump

 

90°Connector

 

Connector

 

out

7.

 

The

 

pump

 

must

 

sit

 

securely

 

on

 

the

 

floor

 

of

 

the

 

tank

 

in

 

an

 

upright

 

position,

 

with

 

its

 

nylon

 

cord

 

attached

 

to

 

the

 

wall

 

of

 

the

 

turret.

 

Outlet

 

pipe

 

must

 

be

 

tightened

 

securely.

 

Pump

 

input

Cartridge

 

filter

 

Priming

 

cap

PTO

 

 

© 2011 Rainwater Harvesting Ltd - All rights reserved. 

Carat with Optimax and Rain Director or Mains Backup 

 

RWH 042 

Rain Director

®

 and Mains Backup in a Box

®

 are registered Trade Marks and may not be used without permission. 

 

Page  2 

 

Содержание Mains Backup in a Box

Страница 1: ...ckup in a Box are registered Trade Marks and may not be used without permission Page 1 Optional Mains Water Backup Optional Rain Director Management System Installation guide Graf Carat rainwater harvesting system with internal filter and Rain Director or Mains Backup in a Box carat_tank_instructions_optimax_mains_backup doc V12 210812 MB ...

Страница 2: ...not remove these as this could invalidate your warranty 5 Pump priming it is essential that the pump is primed by removing the half inch black cap and pouring approximately 5 litres of water into the pump through a funnel failing to do this will cause the pump to burn itself out even if submerged and invalidate your warranty 6 Pump connections output pipe usually supplied and 25mm HDPE runs out of...

Страница 3: ...ength to bring leaf filter to correct level for the input and output 4inch pipes Fit calmed inlet to base of downpipe Ensure 4inch input and output supporting the leaf filter in the turret of the tank are far enough apart to permit removal of the filter for maintenance and to permit removal of the pump 11 Electrical Connect cable from wall socket in building to an IP66 rated junction box or simila...

Страница 4: ...th the upper and lower halves The Graf patented quick connectors wedges secure the two halves together and can be disassembled if you choose For the best results work diagonally in attaching the connectors i e after the first say at 12 o clock secure a connector on the opposite side of the tank at 6 o clock Then secure connectors at 3 o clock and 9 o clock etc This ensures that the seal is compres...

Страница 5: ...ay using concrete will invalidate warranty in terms of our technicians retrieving damaged or faulty parts Ensure the hole is dug to a depth which permits the tank dome cover to be at the required level usually ground level even though the turret has a lot of leeway for final adjustment Complete the mounting of the tank in its final position leaving the surround of the tank dome free for piping Not...

Страница 6: ...rainpipe after the filter should also have a drop of 20 or 50 millimetres to encourage flow away from the filter whether or not the U tube siphon as a rodent and odour guard is fitted 3 If this overflow debris outlet does not go to main drain the soakaway must be constructed to high standard and high volume 4 The soakaway should be of a volume sufficient to ensure that water does not back up to th...

Страница 7: ...o a main drain the soak aw ay must have c apac ity to ens ure water does not back up t o the leaf f ilteri n thet op of t he s torage t ank ot herwise debris will flow into the st ored rai nw ater Soakaway can be c ylindric al c oncrete piping 80 or 100 cms di ameter bore hole or any format but should be1 t o 2 times the volumeof the rainw at er st orage tank 2 Debris and leaf collector if propert...

Страница 8: ... length to run straight upwards to a right angle connector Supplied from which the pipe runs in to the house through the 4 inch service pipe This right angle connector must be within 30cms of the surface of the ground even if extension sleeves are fitted so that it can be undone in the future for removal of the pump Note that it is not permitted under the Water Regulations to feed both mains and r...

Страница 9: ... pipe of this size back to the house in which the feed pipe from the pump and electric cable s can be channelled It is the installer s responsibility to ensure that a services to the house are secure and protected and b connections in the turret permit the later removal of the filter pump and other equipment for inspection maintenance or replacement DEBRIS OUT IN FROM GUTTERS STORED RAIN WATER Ens...

Страница 10: ...ain Director or Mains Backup RWH 042 Rain Director and Mains Backup in a Box are registered Trade Marks and may not be used without permission Page 10 You should read the instructions for your mains backup option or prior to commencing Individual instructions are delivered with the product but you can get a download at any time Rain Director www rainwaterharvesting co uk downloads raindirector_man...

Страница 11: ...nd servicing Page 9 The points described in these instructions must be observed under all circumstances All warranty rights are invalidated in the event of non observance Separate installation instructions are enclosed in the transportation packaging for all additional articles purchased from GRAF Missing instructions must be requested from us immediately The tank must be checked for any damage pr...

Страница 12: ...ection installed on delivery is merely transportation packaging It cannot be walked on and is not child proof it must be replaced with a suitable cover immediately following delivery telescopic dome shaft with corresponding cover Only original GRAF covers or covers approved in writing by GRAF must be used GRAF offers an extensive range of accessories all of which are designed to match each other a...

Страница 13: ... B in areas used by passenger cars without groundwater and stratum water Coverage heights with Begu telescopic dome shaft with cover class D to be provided at construction site in areas used by trucks with a max weight of 12 t without groundwater and stratum water Coverage heights on installation in groundwater the hatched areas specify the permissible immersion depth for the adjacent tank size no...

Страница 14: ...es 13 000 litres Art No 370001 370002 370003 370004 370007 370008 370009 Weight 120 kg 150 kg 185 kg 220 kg 300 kg 370 kg 440 kg L 2080 mm 2280 mm 2280 mm 2390 mm 2280 mm 2280 mm 2390 mm W 1565 mm 1755 mm 1985 mm 2190 mm 4110 mm 4570 mm 4980 mm H 1400 mm 1590 mm 1820 mm 2100 mm 1590 mm 1820 mm 2100 mm Htot 2010 mm 2200 mm 2430 mm 2710 mm 2200 mm 2430 mm 2710 mm 3 Technical data Htot Htot ...

Страница 15: ...Tank dome can be rotated by 360 Tank tank dome seal Carat underground tank Subsoil Covering layer Telescopic dome shaft Carat underground tank Compacted foundation Concrete layer for surfaces Surrounding round grained gravel max used by passenger cars grain size 8 16 5 Installation and assembly ß according to DIN 4124 5 2 3 6 4 1 ...

Страница 16: ...ree area The frost free depth is usually approx 600 mm 800 mm precise information in this regard can be obtained from the responsible authority A layer of compacted round grain gravel grain size 8 16 thickness approx 150 200 mm is applied as the foundation 5 2 1 Slope embankment etc On installation of the tank in the immediate vicinity 5 m of a slope earthen mound or slope a statically calculated ...

Страница 17: ...lled in layers of max 30 cm steps and is compacted The individual layers must be well compacted manuel tamper Damage to the tank must be avoided during compaction Mechanical compaction machines must not be used under any circumstances The surrounding must be at least 500 mm wide 5 4 Routing connections All feed and overflow pipes must be routed with a decline of at least 1 in the direction of flow...

Страница 18: ...e telescope is then greased inserted and aligned with the surface of the site 6 3 Telescopic dome shaft on which persons may walk Important To prevent loads from being transferred onto the tank round grain gravel max grain size 8 16 is filled in in layers around the telescope and is evenly compacted Damage to the tank dome and telescope must be avoided during this step The cover is then positioned...

Страница 19: ...rea surface 1 Adapter max earth cover 1 350 mm 2 Adapter max earth cover 1 500 mm in each case in connection with the Maxi telescopic dome shaft The entire system must be checked for leaks cleanliness and stability at least every three months The entire system should be serviced at intervals of approx 5 years In this case all parts of the system must be cleaned and their function checked Servicing...

Страница 20: ...Page 4 3 Spécifications techniques Page 5 4 Assemblage Page 6 5 Montage Page 6 6 Accessoire Page 8 7 Maintenance Page 8 Outline 1 General advices Page 2 2 Installation conditions Page 4 3 Technical specifications Page 5 4 Assembly Page 6 5 Installation Page 6 6 Accessory Page 8 7 Maintenance Page 8 Inhaltsübersicht 1 Allgemeine Hinweise Seite 2 2 Einbaubedingungen Seite 4 3 Technische Daten Seite ...

Страница 21: ...votre kit GRAF Les notices manquantes sont à récupérer auprès de nos services Avant tout montage il est indispensable de vérifier le contenu du carton Tout article manquant ou non conforme est à signaler immédiatement et ne devra pas être installé L installation doit être réalisé par un professionnel It is indispensable to follow the different instructions of this manual In case of non observance ...

Страница 22: ...ée par un installateur professionnel Durant toute intervention sur les accessoires l installation complète doit être mise hors service Lors de toute intervention sur l installation montage vérification réparations éventuelles les précautions d usage et normes en vigueur sont à respecter Durant toute intervention sur la cuve ou les accessoires l installation complète doit être mise hors service La ...

Страница 23: ... of process water have to be marked with no drinking water in writing or by illustrations according to the relevant domestic rules in order to avoid the wrong connection with the drinking water pipework even after years of use Wrong use may even arise with correct marking e g by children Therefore all process water tappings have to be installed with child safe valves 2 1 Optimax Pro Filter Intern ...

Страница 24: ...Seite 5 von 8 Abmessungen Dimensions Dimensions 3 TECHNISCHE DATEN 3 Technische Daten Spécifications techniques Technical specifications ...

Страница 25: ...z aus Edelstahl Grille filtrante en acier Filter inset Sieve insert in stainless steel Halter für Opticlean Support pour Opticlean Support for Opticlean Filtergehäuse Corps du filtre Filter body 5 Einbau Montage Installation 4 Aufbau Assemblage Assembly 5 1 Übersicht Aperçu du filtre Overview ...

Страница 26: ...lten verbinden Alle Verbindungsstellen mit han delsüblichen Spaxschrauben gegen auseinander rutschen si chern Raccorder le corps de filtre au tuyau anti remous PCV DN 100 fourni et compris dans le pack accessoire n 3 Le sabot anti remous est à raccorder et à utiliser uniquement pour les cuves de capacités de 7800 L et 9200 L Les connexions sont à bloquer à l aide de vis types vis à bois pour évite...

Страница 27: ...h the spannfix collar contained in filter package 3 5 Einbau Montage Installation Je nach Schmutzanfall im Dachablaufwasser muss die Siebfläche des Optimax Pro Filters mehrmals im Jahr gereinigt werden Beim Abnehmen des transparenten Deckels bleibt der Siebeinsatz an diesem hängen und kann somit problemlos entnommen und gereinigt werden Nettoyer plusieurs fois par an le filtre Optimax Pro pour enl...

Отзывы: