28
EC4 100 CV
DEMAND INITIATED TREATMENT SYSTEM
DEMAND INITIATED
WATER TREATMENT SYSTEM
CALIFORNIA
PERFORMANCE DATA SHEET
· SERVICE FLOW RATE = 10.0 GPM (37.8 LPM)
· DRAIN FLOW RATE: 2.0 GPM (7.6 LPM)
· PSI DROP @ FLOW RATE: 12.0 psi (0.9 kgf/cm2)
· Operating PSI of supply: 20 psi - 120 psi (1.47 - 8.45 kgf/cm2)
· Operating temperature: 40° F - 100° F (4.4° C - 38° C)
· Electrical: 24 VDC 50/60 hz (COMPUTER)
· SALT PER REGENERATION: VARIABLE
· Salt Efficiency: 4,750 GRAINS/LBS. SALT @ 3.0 LBS. DOSAGE
CAPACITY AND SALT SETTINGS
CAPACITY
SALT
14,200 GRAINS
@ 3.0 LBS. OF SALT
30,500 GRAINS
@ 10.0 LBS. OF SALT
34,500 GRAINS
@ 15.0 LBS. OF SALT
LIST OF CONTAMINANTS REDUCED
*HARDNESS WAS USED AS A SURROGATE FOR BARIUM AND RADIUM REDUCTION
CLAIMS PER NSF/ANSI STANDARD 44.
CONTAMINANT
USEPA
MCL
BARIUM*
2 PPM
RADIUM 226/228*
5 PCI/L
NSF/ANSI STANDARD 44 TEST CONDITIONS: 35 ± 5 psi, 65 ± 10°F, pH 7.5 ± 0.5 at
service flow rate
CHALLENGE
AVERAGE INFLUENT
LEVEL
AVERAGE EFFLUENT
LEVEL
HARDNESS
335 PPM
8 PPM
SOFTENING PERFORMANCE TEST
NSF/ANSI STANDARD 44 TEST CONDITIONS: 35 ± 5 psi, 65 ± 10°F, pH 7.5 ± 0.5 at
service flow rate
ADDITIONAL NOTES
• THE LIST OF SUBSTANCES WHICH THIS TREATMENT DEVICE
REDUCES DOES NOT NECESSARILY MEAN THAT THESE SUBSTANCES
ARE PRESENT IN YOUR WATER SUPPLY.
• ACTUAL RESULTS MAY VARY DUE TO LOCAL WATER CONDITIONS.
• AN EFFICIENCY RATED WATER SOFTENER IS A DEMAND INITIATED
REGENERATION SOFTENER, WHICH ALSO COMPLIES WITH SPECIFIC
PERFORMANCE SPECIFICATIONS INTENDED TO MINIMIZE THE AMOUNT
OF REGENERATE BRINE AND WATER USED IN ITS OPERATION AND WILL
ACHIEVE A RATING OF NOT LESS THAN 3,350 GRAINS OF TOTAL HARD-
NESS EXCHANGE PER POUND OF SODIUM CHLORIDE SALT AND SHALL
NOT DELIVER MORE SALT THAN ITS LISTED RATING. THE EFFICIENCY
IS MEASURED BY A LABORATORY TEST DESCRIBED IN NSF/ANSI 44.
THE TEST REPRESENTS THE MAXIMUM POSSIBLE EFFICIENCY THAT
THE SYSTEM CAN ACHIEVE. OPERATIONAL EFFICIENCY IS THE ACTUAL
EFFICIENCY ACHIEVED AFTER THE SYSTEM HAS BEEN INSTALLED AND
IS TYPICALLY
LESS THAN THE TESTED EFFICIENCY DUE TO
INDIVIDUAL APPLICATION FACTORS INCLUDING WATER HARDNESS,
WATER USAGE, AND OTHER CONTAMINANTS THAT REDUCE THE SOFT-
ENERS CAPACITY.
• A WATER SOFTENER IS NOT INTENDED TO BE USED FOR TREATING
WATER THAT IS MICROBIOLOGICALLY UNSAFE OR OF UNKNOWN
QUALITY WITHOUT ADEQUATE DISINFECTION BEFORE AND AFTER THE
SYSTEM.
• EFFICIENCY OF THE CONDITIONER IS VALID ONLY AT THE STATED
SALT DOSAGE.
THE SYSTEM SHOULD BE INSTALLED IN AN AREA NOT
AFFECTED BY EXTREME HEAT, COLD, OR THE ELEMENTS.
THIS SYSTEM MUST BE INSTALLED IN ACCORDANCE WITH
ALL APPLICABLE STATE AND LOCAL LAWS AND REGULATIONS.
DO NOT INSTALL SYSTEM WHERE WATER IS
MICROBIOLOGICALLY UNSAFE OR OF UNKNOWN QUALITY
WITHOUT ADEQUATE DISINFECTION BEFORE OR AFTER
THE SYSTEM.
THE SYSTEM CONTAINS AN ION-EXCHANGE MEDIA
FOR REMOVING LISTED CONTAMINANTS AND MUST BE
REGENERATED PERIODICALLY. PLEASE REFER TO THE
OWNERS MANUAL TO DETERMINE THE FREQUENCY OF
REGENERATIONS.
PLAIN, WHITE BLOCK SALT IS RECOMMENDED FOR THIS
SYSTEM. IF BLOCK SALT IS NOT AVAILABLE, A CLEAN,
COARSE OR EXTRA COARSE BAG SALT MAY BE USED. DO NOT
USE GRANULATED SALT. CONSULT YOUR RAINSOFT DEALER
FOR POTASSIUM CHLORIDE USE.
YOUR LOCAL DEALER IS AVAILABLE FOR SERVICE AND
WARRANTY PART REPLACEMENTS.
CALIFORNIA STATE WATER RESOURCE CONTROL BOARD
REGISTRATION NUMBER-1802
SEE THE OWNERS MANUAL FOR GENERAL OPERATION AND
MAINTENANCE REQUIREMENTS.
SEE WARRANTY CARD FOR SPECIFIC WARRANTY INFORMATION.
IMPORTANT NOTICE
READ THIS PERFORMANCE DATA SHEET AND COMPARE
THE CAPABILITIES OF THIS UNIT WITH YOUR ACTUAL
WATER TREATMENT NEEDS. IT IS RECOMMENDED THAT
BEFORE PURCHASING A WATER TREATMENT UNIT, YOU
HAVE YOUR WATER SUPPLY TESTED TO DETERMINE YOUR
ACTUAL WATER TREATMENT NEEDS.
C
US
TESTED AND CERTIFIED BY NSF INTERNATIONAL TO
NSF/ANSI STANDARD 44 AND CSA B483.1 FOR THE
REDUCTION OF THE CLAIMS SPECIFIED ON THE
PERFORMANCE DATA SHEET.
TESTED AND CERTIFIED BY THE WQA TO NSF/ANSI
STANDARD 44 FOR THE SPECIFIC PERFORMANCE CLAIMS
AS VERIFIED AND SUBSTANTIATED BY TEST DATA.
TESTED AND CERTIFIED BY THE WQA TO NSF/ANSI
STANDARD 372 FOR LOW LEAD COMPLIANCE. THE
EC4 SERIES IS TESTED AND CERTIFIED BY WQA TO
CSA B483.1 STANDARD.