background image

21

System Alarms

Your system is equipped to alert you for alarm situations: When 

Alarm is active, your EC4 will display the Alarm Status on the Main 

Screen. 

Salt Alarm

 if “ON” the alarm will sound at the time set for low salt, 

no salt conditions. When the alarm is active you have the option to 

silence the alarm by postponing the alarm for 10 of days as a reminder 

to add more salt. Once more salt is added to brine tank, increase your 

salt level over 0.5 to end low salt condition.

Service Alarm

 was set for systems that require routine maintenance. 

These alarms can be postponed for 10 of days. Contact your local 

RainSoft Dealer when service alarms are active to schedule a service.

Other Alarms 

- If issue with the motor  is detected by the valve 

control, an alarm will activate. This alarm can be postponed for 10 

Days, but please contact your local RainSoft Dealer immediately for 

a service.

Info Center

The Information Center provides general information about your 

EC4 System. To access this information, press the 

Right Arrow 

button from the Home screen.

•  Size:

 listing the Model / Size / Type of media

• 

System Status: 

listing current status of the EC4. 

• 

Salt Lvl:

 listing the current amount of salt and level

• 

Salt Alarm:

 status of salt alarm Off / On & time set.

• 

Regen Time: 

displays current time set for regeneration.

• 

 Avg Daily Water:

 average water use in per day averaged over 28 

day period.

• 

 Weekly Salt Use:

 average weekly salt used per week averaged 

over 4 week period.

• 

Current Flow:

 showing current flow rate of water thru outlet.

• 

Flow Since Regen:

 total water used since last regeneration.

• 

Hardness:

 listing the water hardness setting in EC4.

• 

Iron:

 listing the water iron setting in EC4

• 

 Est Next Regen:

 the estimated number of days until the next 

regeneration, based on water use and history.

•  Vacation Mode: 

listing days remaining if active.

• 

Conditioner Install:

 listing the date of EC4 installation.

• 

 House Filter Service Reminder (if enabled):

 listing the 

months remaining before service is required.

• 

 Drinking Water Service Reminder (if enabled):

 listing the 

months remaining before service is required. 

• 

 AirMaster Service Reminder (if enabled):

 listing the months 

remaining before service is required. 

•   CleanStart Service Reminder (if enabled)

: listing the months 

remaining before service is required.

• 

Web Address:

 web site for more info www.rainsoft.com.

• 

 For Service Call:

 Programmed RainSoft Service Providers 

phone number.

To exit the Information Center

, press and hold the 

Enter

 button at 

any time then select “YES” to exit

 

or continue to press

 Right 

button

,

 

to end of selections to exit automatically.

!

Important Note: The Information 

Center is a display only mode and 

will not allow any changes to the 

settings or current service run 

data.

!

Important Note: Current Flow and 

Flow since last regen are live 

functions and will count up as the 

water is used and flowing.

!

Important Note: Next Regen 

estimate is based on water 

consumption. It may take 14 

days after start up to provide an 

accurate estimate.

!

Important Note: The average 

water use will be accurate 7 days 

after start up.

Helpful Tip: Disabling the alarm 

is not required if you add salt 

before the selected number of 

postponement days.
Please refer to the“Customer 

Settings” on page 13 for 

instructions on adding salt.

Helpful Tip: To silence the alarms, 

press any key.

!

Important Note: Accessory 

Systems Service Reminders 

interval settings by the installers 

based on incoming water 

conditions and recommend 

product specifications. Not all 

accessory items require service 

reminders, not all accessory items 

are available. Inquire to your 

local RainSoft Dealer for more 

information.

Содержание EC4 SERIES

Страница 1: ...ries is tested and certified by WQA to CSA B483 1 Standard Part No 50038 Rev B 10 20 Rainsoft Division of Aquion Inc 101 S Gary Ave Roselle Illinois 60172 1 847 437 9400 or 1 800 860 7638 www rainsoft...

Страница 2: ...m Start Up 13 Salt Requirements 15 Maintenance Requirements 15 An Overview of the Regeneration Process 16 17 EC4 Display Home Screen 17 Customer Setting Flow Chart 18 Customer Settings 19 20 How to In...

Страница 3: ...ht amount of salt for maximum efficiency based on your individual water consumption needs Application Limitations On hardness levels of 60 grains and higher the system may not achieve a hardness of le...

Страница 4: ...where water is microbiologically unsafe or of unknown quality without adequate disinfection before or after the system This system must be installed in accordance with all applicable state and local...

Страница 5: ...10 0 2 0 10 0 34 500 15 0 lbs 30 500 10 0 lbs 14 200 3 0 lbs 4 750 3 0 lbs EC4 100 CV 10 x 44 1 0 10 0 2 0 11 0 34 500 15 0 lbs 30 500 10 0 lbs 14 200 3 0 lbs 4 750 3 0 lbs EC4 100S V 10 x 35 1 0 10...

Страница 6: ...2 0 11 0 30 500 15 0 lbs 26 100 10 0 lbs 13 500 3 0 lbs 4 516 3 0 lbs EC4 150 T 10 x 54 1 5 9 6 2 0 12 0 45 700 22 5 lbs 39 200 15 0 lbs 20 300 4 5 lbs 4 516 4 5 lbs EC4 150 CT 10 x 54 1 5 9 6 2 0 13...

Страница 7: ...liance The EC4 Series is tested and certified by WQA to CSA B483 1 Standard Water treatment devices sold to retail consumers in California accompanied by certain health claims must be registered to Ca...

Страница 8: ...or shed In some installation environments you may choose to partially bury the system This is done primarily for aesthetics however this will add stability to the system as well We do recommend all s...

Страница 9: ...ns of pipe between the system and the water heater If you cannot avoid a short connection move the system to another location As a last resort install a heat trap or check valve If this causes water h...

Страница 10: ...let pipe connection of the yoke When looking at the front of the system the inlet is the pipe connection on the right side of the valve see figure 3 The arrow molded into valve indicates the direction...

Страница 11: ...in line to the air gap The air gap should be installed between the end of the drain line and the drain to prevent possible back siphoning see figure 6 11 Figure 5 Mr Drain AIR GAP STAND PIPE FOR WASHE...

Страница 12: ...bout 5 inches from the overflow elbow see figure 7 3 11 Install the Brine Line Slide the brass compression nut over the end of the brine line followed by the ferrule and tube support Attach the brine...

Страница 13: ...e Remaining Debris from the System Open the cold water faucet on your bathtub Allow the system to flush the remaining dirt and debris into the bathtub until the water runs clear Open all remaining fau...

Страница 14: ...locks Standard Block Dims 8 5 x 8 5 x 11 5 Total Blocks Possible 3 150 lbs of Salt Level 4 0 level equal to 200 lbs Not Correct STACKING BLOCK SALT 50 lbs BLOCKS 11 5 8 5 8 5 STACKING BLOCK SALT 25 lb...

Страница 15: ...s Your water quality and the amount of regenerations necessary will affect this maintenance schedule Your local RainSoft Dealer is knowledgeable in the different water qualities and will have the nece...

Страница 16: ...ed the control will calculate the exact amount of salt that you will need to restore the system capacity Then 2 hours before the time of regen the control will start to fill just enough water to the b...

Страница 17: ...manual regeneration mode available Regen Now See the How to Initiate a Manual Regeneration in this manual on how start a manual regeneration An example of when to use a manual regeneration would be if...

Страница 18: ...hrough the menu s list of functions While in regeneration press and hold to advance valve to next cycle While in regeneration press and hold to cancel the regeneration and send valve to service positi...

Страница 19: ...ay 2 Days Use the Up and Down button to change the number of days away Salt Alarm OFF ON 5 00 PM Off On setting that will enable an audio alarms to sound when the system has low salt The Audio alarm w...

Страница 20: ...cess if initiated in error by pressing and holding the Right Arrow Button To initiate a Regen Later Follow the same steps from above however press the Right Arrow button to select No press the Enter R...

Страница 21: ...ed number of days until the next regeneration based on water use and history Vacation Mode listing days remaining if active Conditioner Install listing the date of EC4 installation House Filter Servic...

Страница 22: ...22 Valve Exploded View 9 8 7 5 4 3 2 1 6 27 ABCD 22 23 24 10 25 30 31 AB 28 11 12 32 13 17 14 15 16 26 ABCDE 29 18 19 20 AB 21...

Страница 23: ...ILL FLOW CONTROL 0 5 GPM COMPOSITE 21 1 17957 ADAPTER BLFC 0 25 GPM 22 1 17939 1 2 NPT X 1 2 BARB POLY ELBOW 23 1 17557 COMPOSITE BYPASS VALVE 24 1 17558 TURBINE METER ASSEMBLY WITH CABLE 25 1 17812 R...

Страница 24: ...Control Exploded View 24 6 6 EC4 TECHNOLOGY 12 19 4 10 14 8 1 7 9 13 8 15 17 16 18 6 8 1 2 3 9 1 5 EC4 LOGO PAD PRINTED 11...

Страница 25: ...918 SCREW 1 4 20 X 1in PHIL PAN SS 8 6 51919 SCREW 4 20 x 1 4in PHIL PAN PLASTITE 9 1 51921 RPS SOFTENER VALVE MOTOR ASSY 9 1 1 17501 BRINE GEAR CAM 10 1 52461 FRONT HOUSING GEN6 11 1 52463 DOOR BUTTO...

Страница 26: ...ypass valve 3 Poor water quality 1 Low pressure to the unit 1 Bypass the system If the problem still exists after bypass it is not related to a RainSoft product Check your water distribution system If...

Страница 27: ...GATE FOR BARIUM AND RADIUM REDUCTION CLAIMS PER NSF ANSI STANDARD 44 ADDITIONAL NOTES THE LIST OF SUBSTANCES WHICH THIS TREATMENT DEVICE REDUCES DOES NOT NECESSARILY MEAN THAT THESE SUBSTANCES ARE PRE...

Страница 28: ...TESTED EFFICIENCY DUE TO INDIVIDUAL APPLICATION FACTORS INCLUDING WATER HARDNESS WATER USAGE AND OTHER CONTAMINANTS THAT REDUCE THE SOFT ENERS CAPACITY A WATER SOFTENER IS NOT INTENDED TO BE USED FOR...

Страница 29: ...TESTED EFFICIENCY DUE TO INDIVIDUAL APPLICATION FACTORS INCLUDING WATER HARDNESS WATER USAGE AND OTHER CONTAMINANTS THAT REDUCE THE SOFT ENERS CAPACITY A WATER SOFTENER IS NOT INTENDED TO BE USED FOR...

Страница 30: ...ges so parts of the above limitation or exclusion may not apply to you This warranty gives you specific legal rights and you may also have other rights which vary from state to state You also have imp...

Страница 31: ...31...

Страница 32: ...RainSoft Division of Aquion Inc 101 S Gary Avenue Roselle Illinois 60172 Main Switchboard 1 847 437 9400 Customer Service 1 800 860 7638 www rainsoft com 2013 RAINSOFT A DIVISION OF AQUION INC...