Weather Station Manual
Rain Master Irrigation Systems
Page 30
Note: If the Flow Max feature is utilized on the controller that the Weather Station
is connected to, then the user must say Flow Meter is connected to this
controller. During the Flow Max Set-Up (Refer to DX2 User Guide pages F-
22 & F-23) the “K” and offset values of “0” must be entered at the
submaster (Refer to DX2 User Guide).
Check cable continuity
from the terminal block to
the Sensor Terminal Board
Check and repair cable
continuity from terminal
block to ET Tracker
Check 6 Volt transformer
and connections. Repair/
Replace as necessary.
Repeat the Priming
Process
1
Can +8 Volts DC be
measured at the ET
Terminals of the
Weather Station
terminal block?
No
Yes
Can +8 Volts DC
be measured at the
Terminal block of
the ET Tracker
connecting plug?
No
Can +6 Volts DC
be measured at the
ET Tracker supply
input on the
Terminal block?
Yes
No
Yes
End
8
6
5
7
Содержание ET Tracker
Страница 1: ...Weather Station User Manual ET Tracker Rain Sensor Wind Sensor March 2001Document Number 500009 Rev C ...
Страница 2: ......
Страница 3: ...Rain Master Irrigation Systems Weather Station Weather Station ...
Страница 4: ......
Страница 8: ...Rain Master Irrigation Systems Weather Station Manual Page 3 Figure 1 Weather Station Configuration ...
Страница 11: ...Weather Station Manual Rain Master Irrigation Systems Page 6 Figure 2 Weather Station Tower Base ...