Rain Master Irrigation Systems
Weather Station Manual
Page 5
8 foot step ladder
1
PVC Conduit 1 inch, for tower base
wiring. 4
feet
PVC 1 inch elbow
1
Water container, for Top cup assembly
immersion 1
Table 3: Required Materials
Part Number
Description
Quantity
Concrete and masonary Sand
1
Standard masonary tools
1
Gallon of Distilled Water
1
1.2 General
The mounting bolts for the Rain Gauge, Wind Sensor and tower mounting bracket, are
pre-installed on the tower mast. These bolts will need to be removed prior to assembly
and installation
.
2.0 Weather Station Installation
Use the following step to assembly the Weather Station tower.
Step 1
Prepare and pour a concrete support slab according to the enclosed
drawing, see Figure 2: Weather Station Tower Base. Use the provided
template to set the 5/16" mounting bolts. The bracket must be level
and plumb. The conduit should extend at least 2 inches above the
horizontal plate.
Step 2
Install the 8 conductor cable (EV-CAB-WS) from the controller to the
Weather Station through the conduit. From the Weather Station to the
controller allow a minimum of 36 inches of cable to extend beyond the
conduit into the controller’s pedestal cabinet. On the Weather Station
tower, allow a minimum of 70 inches of cable to extend beyond the
conduit into the Weather Station mast
assembly.
Содержание ET Tracker
Страница 1: ...Weather Station User Manual ET Tracker Rain Sensor Wind Sensor March 2001Document Number 500009 Rev C ...
Страница 2: ......
Страница 3: ...Rain Master Irrigation Systems Weather Station Weather Station ...
Страница 4: ......
Страница 8: ...Rain Master Irrigation Systems Weather Station Manual Page 3 Figure 1 Weather Station Configuration ...
Страница 11: ...Weather Station Manual Rain Master Irrigation Systems Page 6 Figure 2 Weather Station Tower Base ...