INSTALLATION INSTRUCTIONS • 15
Using the Cutters, make a clean cut to the Fluid
Line.
Insure the cut is clean, and perpendicular to
avoid any leaks, this is very important.
Slide the supplied Heat Shrink over the Fluid
Line. Remove the Elbow, using a fingernail to
depress the Legris, from the Hub. Insert it into
the cut section of the Fluid Line.
16
Slide the Heat Shrink over the end, making sure
to cover both the Fluid Line and the Legris. Make
sure not to overheat the part.
17
18
Locate the remaining piece of 1/4” Fluid Line that
was provided from the Pod installation.
Take the male end of the CPC Connector and
plug it into the output side of the Pod and run the
Fluid Line towards the Hub.
13
Mark the Fluid Line, leaving a bit of extra Line so
that it doesn’t bind or kink. Use the end of the
Elbow as a guide of where to cut the Line.
14
15
Содержание FLUIDLOGIC