Rain Master Irrigation Systems
Weather Center II User Manual
Page 51
displayed on the RME Eagle Controller display.
Step 2
Disconnect the the cable harness from J12 on the RME
Eagle Controller. Using a short wire (14 - 12 AWG)
touch end to pin 5 of J12 and the other side to pin 6 of
J12.
Step 3
Observe the controller ET display screen and note the
present ET value for today. (Refer to the RME Eagle User
Manual on Reading ET Values at the Controller)
Step 4
Touch the two ends of the wires to the terminal pins 5 and
6 momentarily 2 or 3 times. (An ET reading of 0.01 inches
should be recorded each time the wires make contact with
the terminal pins)
Step 5
Re-check the ET values on the RME Eagle Controller ET
display screen. Verify that the readings have increased by
0.01 inches (1/100 inch) for each time the wires made
contact.
Step 6
This ends of ET Data Checkout procedure. If the ET value
does not increase each time the wires are shorted, verifiy
that the correct terminals pins are being touched. If no
readings are registered contact Rain Master technical
support for assistance.
Содержание Weather Center II
Страница 1: ...Weather Center II User Manual Part 500009 Rev D...
Страница 2: ...Weather Center II...
Страница 3: ......
Страница 7: ......
Страница 17: ...Weather Center II User Manual Rain Master Irrigation Systems Page 10 Figure 4 Eyebolt Assembly Procedure...
Страница 20: ...Rain Master Irrigation Systems Weather Center II User Manual Page 13 Figure 7 Weather Center Tower Mounting...
Страница 23: ...Weather Center II User Manual Rain Master Irrigation Systems Page 16 Figure 9 Weather Center Terminal Access...
Страница 25: ...Weather Center II User Manual Rain Master Irrigation Systems Page 18 Figure 11 Evolution DX2 Wiring Detail...
Страница 65: ...3910 B Royal Avenue Simi Valley California 93063 Telephone 805 527 4498 Fax 805 527 2813 www rainmaster com...