Page
42
1 Month -
•
Check the temperature/relative
humidity sensor for contamination.
6 Months -
•
Clean the temperature/relative
humidity sensor.
•
Check battery by disconnecting the
AC Power and allow it to stabilize
for at least 2 hours. Then check the
voltage. Reconnect battery to AC
Power.
1 Year -
•
Replace the RH chip if necessary.
2 Years -
•
Calibrate the Pyranometer (some
suggest yearly).
•
Replace RH chip in Air Temp/RH
Sensor.
•
Calibrate the Tipping Bucket Rain
Gage. To check accuracy of the rain
gage - 16 ounces of fluid is equal
to 1” of rainfall. Fluid must be
poured into the gage
VERY
SLOWLY
to get an accurate bucket
tipping count.
4 - 5 Years -
•
Replace sensor cables as requires.
General Maintenance
•
An occasional cleaning of the glass
on the solar panel will improve its
efficiency.
•
Check sensor leads and cables for
cracking, deterioration, proper
routing and strain relief.
•
Check the tower for structural
damage, proper alignment and for
level/plumb.
Содержание WS-PRO
Страница 1: ...WS PRO Weather Station INSTALLATION MAINTENANCE AND TROUBLESHOOTING MANUAL November 2004 GT27145D...
Страница 2: ......
Страница 10: ...Page viii...
Страница 16: ...Page 6 FIGURE 2 MAGNETIC DECLINATION FOR THE CONTIGUOUS UNITED STATE...
Страница 21: ...Page 11 FIGURE 4 CONCRETE BASE DETAIL FIGURE 5 ANCHOR BOLT TEMPLATE DETAIL...
Страница 24: ...Page 14 FIGURE 6 EXTERNAL WIRING DETAIL AT THE PRO SH WEATHER STATION...
Страница 27: ...Page 17 FIGURE 7 EXTERNAL WIRING DETAIL AT THE PRO PH WEATHER STATION...
Страница 33: ...Page 23 FIGURE 10 SOLAR PANEL INSTALLATION DETAIL...
Страница 35: ...Page 25 FIGURE 11 CROSS ARM MOUNTING INSTALLATION OF 034A WIND SENSOR...
Страница 48: ...Page 38 FIGURE 21 INSTALLATION AT CENTRAL COMPUTER FOR DIRECT CONNECTED WEATHER STATION...
Страница 50: ...Page 40 FIGURE 22 INSTALLATION AT CENTRAL COMPUTER FOR TELEPHONE CONNECTED WEATHER STATION...
Страница 73: ...Page 63 FIGURE 28 TYPICAL 3 ROD GROUNDING GRID DETAIL...
Страница 74: ...Page 64 2 Ht o E 2 p i n s 1 t o 3 4 2 Ht o A G p i n s 1 t o 2 FIGURE 29 TESTING OF WIND SENSOR...
Страница 75: ...Page 65 FIGURE 30 TESTING OF SOLAR RADIATION SENSOR...
Страница 76: ...Page 66 FIGURE 31 TESTING OF RAIN GAGE...
Страница 77: ...Page 67 FIGURE 32 TESTING OF TEMPERATURE RELATIVE HUMIDITY SENSOR...
Страница 78: ...Page 68 FIGURE 33 TESTING OF AIR TEMPERATURE PROBE...