13.1.15 Set Flow Actions
There are 3 options available to Set Flow Actions during High or Low flow:
• Diagnose & Eliminate
• Shut Down & Alarm
• Alarm Only
1
Turn the controller dial to Flow Sensor
2
At the FLOW SENSOR screen, press the key to select “
Set FloWatch
”, then press
Next
.
3
At the FloWatch screen, press the key to select “
Set Flow Actions
”, then press
Next
.
4
At the Action Under High Flow screen, press the and keys to set the desired option
to occur under High Flow, then press
Next
5
At the Action Under Low Flow screen, press the and keys to set the desired option
to occur under Low Flow, then press
Next
6
At the Re-enable time screen, press the and keys to set the desired number for
hours (from 0 to 23). Press the Arrow keys to navigate between the number setting
fields. Set the minutes (from 0 to 59).
13.1.16 Current Flow Reading
Occasionally it may be useful to check the current flow rate in a particular FloZone and how that
compares to previously learned or user input station flow rates.
1
Turn the controller dial to Flow Sensor
2
At the FLOW SENSOR screen, press the key to select “
Set Current Flow Reading
”, then
press
Next
.
3
At the View Current Flow screen, press the and keys to select the desired FloZone
number. Current and expected flow will show.
•
Expected flow is from previously user-entered or learned station flow rates. The deviation or percentage
comparison of current flow to expected flow will show so you can see how close each FloZone is to a High
Flow or Low Flow condition (see
Setting Up High Flow and Low Flow
for more details).