Current Section:
Flow Sensor 68
Navigation:
13.1.14 Set Up and Configure High Flow and Low Flow
FLOW SENSOR
Next
Flow Sensors
Set Flow Rates
Set FloManager
Set FloWatch
Current Flow Reading
Set Flow Units
FloWatch
Next
FloWatch On/Off
Set Flow Limits
Set Flow Actions
1
Turn the controller dial to Flow Sensor
2
At the FLOW SENSOR screen, press the key to select “
Set FloWatch
”, then press
Next
.
3
At the FloWatch screen, press the key to select “
Set Flow Limits
”, then press
Next
.
4
At the High Flow Settings screen, press the and keys to set the desired High Flow
Threshold percentage (Max. 200%). Then press the key.
5
Press the and keys to set the desired High Flow settling time (Up to 10 minutes ),
then press
Next
.
•
Press and HOLD keys to accelerate settings.
High Flow Settings
Next
High Flow
Threshold
120
%
Settling
Time
03Mins
Low Flow Settings
Next
High Flow
Threshold
070
%
Settling
Time
03Mins
6
At the Low Flow Settings screen, press the and keys to set the desired Low Flow
Threshold percentage (Max. 95%). Then press the key.
7
Press the and keys to set the desired Low Flow settling time (Up to 10 minutes ).
•
Press and HOLD keys to accelerate settings.