This section relates to the following models only:
HN-G-01-1-XXX, HN-G-02-1-XXX
4. Electrical Installation
4.4.1
If 110 VAC is Available
Plug in AC power adapter.
IMPORTANT
If installed outdoors power adapter must be plugged into a weather protected outlet.
4.4.2
If Battery Powered
1.
Remove the top gray cover (push up the sides over the indent).
2.
Remove the black battery tray and install the 4x “D Cell” batteries as shown.
3.
The controller will come to life. It goes to sleep quickly, holding down any of the three lower buttons for a few seconds’ wakes it back up.
4.
Press the far right (M) button on backwash controller to test that the installation