Troubleshooting

Decoders

Use one or two screws at the top and one at the 

bottom, depending on support.

On when power is on. LED is controlled by 

processor. Will not turn on if no firmware is 

downloaded. Blinks when there is an error 

condition (see below).

CAUTION

Mains- and system-ground are 
not internally connected and must 
be separated to provide the best 
protection against surges.

Normally off. Blinks when data is 

received

 from PC.

Normally off. Blinks when data is 

sent

 to PC.

Line indicator, toggles between red and green with 

line voltage polarity.

Switches for disconnection of line with problem.

Serial cable, 9 PIN-9 PIN for PC communication.

Field wires. Up to four two-wire paths may be 

connected.

INSTAllATION DeTAIlS

 

(LARGE AND SmALL DECODER INTERFACE)

lOCATING A BAD DeCODeR uSING A ClAmp meTeR

SENSOR 1 (e.g. Rain Sensor)

SENSOR 2 (Not Shown) (e.g. Alarm Sensor)

To System Ground

Connect to 24 VAC 

transformer

During power up, the LED’s will blink in sequence ending with POWER LED on for 5 seconds. 

If the POWER LED blinks, it means that an 

error

 is detected by the unit. The reason for the error is indicated by the other LED’s:

•  If 

DATA->PC

 is 

ON

 = line voltage has been switched off because connection to the PC is lost.

•  If 

LINE

 is 

ON

 = line voltage is below 25 V (short).

•  In the Decoder Diagnostics screen select 60Hz test mode to allow the clamp meter to measure current. When done with 

troubleshooting remember to cancel the 60Hz test mode to resume irrigation.

VOLT METER

33 VOLTS ± WHEN IN 60Hz TEST MODE

33v±

0.5±

1.0±

0.5±

BAD

DECODER

CAM

CLAMP METER

HIGHER 

THAN 

CAL

CULA

TED 

VA

LU

E

HIGHER 

THAN 

CAL

CULA

TED 

VA

LU

E

HIGHER THAN 
CALCULATED VALUE

HIGHER 

THAN 

CAL

CULA

TED 

VA

LU

E

LESS 

THAN

 CAL

CULA

TED 

VA

LU

E

LESS THAN CALCULATED VALUE

HIGHER THAN 
CALCULATED 
VALUE

4

Содержание FD-101

Страница 1: ...llation requires up to 80 percent less wire than conventional controller systems Electronic components are completely encapsulated to protect against the elements And system expansion is easy simply s...

Страница 2: ...mine the total calculated current draw of the wire path 3 To calculate the static current draw of an entire interface add up all calculated wire path current draws that are connected to the interface...

Страница 3: ...d wire path with short condition LED will be solid when shorted wire path is activated Disconnect field wires and recheck voltage Reconnect field wire Compare expected and actual at rest current draw...

Страница 4: ...ION DETAILS Large and small Decoder Interface Locating a bad decoder using a Clamp meter SENSOR 1 e g Rain Sensor SENSOR 2 Not Shown e g Alarm Sensor To System Ground Connect to 24 VAC transformer Dur...

Страница 5: ...t Run ON OFF Test in Decoder Diagnostics to Validate System Operation Repeat to narrow down location of wire path short Choose point halfway between measurement point and end of wire path Break critic...

Страница 6: ...determine exact location of broken wire or partial connection Bad Splice Turn on first wire path Compare expected actual at rest current draw to expected current draw in Decoder Diagnostic window in c...

Страница 7: ...fy at rest current draw matches expected current draw Run ON OFF test to validate system operation At LDI disconnect wire with lower draw and choose point halfway to end of wire path Measure draw in c...

Страница 8: ...Corporation 6991 East Southpoint Road Tucson AZ 85756 U S A Phone 800 984 2255 520 741 6100 Fax 520 741 6522 Email rbgolf rainbird com Technical Service and Support 800 RAINBIRD U S and Canada only R...