background image

12

© Copyright 2021. All rights reserved.

REPLACEMENT PARTS LIST

E

D

C

B

A

F

Motor

Assembly

To order parts, call 1-866-544-1406

HP

1

1-1/2

ITEM

SINGLE PHASE

MODEL NO.

BPUMP1HP

BPUMP1-5HP

DESCRIPTION

PART NO.

A
B

Ring, Square Cut
Seal, Rotary and Ceramic (with 

Spring)

Call for 

Replacement 

Part Kits

1
1

1
1

C
D
E
F

Impeller
Diffuser
Diffuser Insert
Rubber Diffuser

Call for 

Replacement 

Part Kits

1
1
1

1
1
1

(*)   Standard hardware item 
NOTE: Motor assembly not available as a replacement part.

PRODUCT SPECIFICATIONS

Model #

HP Suction Lift 

(Ft.)

Discharge Pressure (PSI)

Shut Off 

Pressure  

@ 0 Lift (PSI)

Suction 

Pipe

Discharge 

Pipe

15

20

25

30

35

40

45

Capacity - U.S. Gallons per Minute

BPUMP1HP

1

5

65

61

53

44

32

39

2 in.

1-1/2 in.

10

64

58

49

39

24

15

62

55

45

34

20

59

51

41

28

25

56

46

36

2

BPUMP1-5HP 1-1/2

5

66

63

59

54

48

40

8

45

2 in.

1-1/2 in.

10

64

61

57

52

45

28

15

63

60

55

49

41

15

20

62

58

53

46

32

25

60

56

50

42

21

Max. Case Pressure: 100 PSI

D41966

Содержание BPUMP1-5HP

Страница 1: ...WARNING ELECTRICAL SHOCK ALERT Follow all local electrical and safety codes as well as the National Electrical Code NEC and the Occupational Safety and Health Act OSHA ELECTRICAL SHOCK ALERT Replace...

Страница 2: ...not included 1 Priming Plug with Pressure Gauge Used instead of a priming plug alone Helps determine if the pump is primed indicates if the pump is operating properly and what kind of pressure is in...

Страница 3: ...e water as long as the pump is within 25 vertical feet of the water source Horizontal Distance The horizontal distance is the horizontal measurement between the pump inlet and the water source This di...

Страница 4: ...op of the pump 2 Glue a 6 in piece of 1 1 2 in pipe into the adaptor 3 Glue a 1 1 2 in tee to the pipe 4 Glue a 1 1 2 in slip x 1 1 4 in adaptor to the top opening of the 1 1 2 in tee 5 Thread in a 1...

Страница 5: ...n in the well 14 Glue a 90 elbow when the inlet pipe is in line with the inlet port of the pump For Surface Water Installations For surface water installations follow steps 11 and 12 above and then 15...

Страница 6: ...o the female portion of the 1 1 2 in union 5 Glue 1 1 2 in ball valve to the other end of the 6 in piece of pipe 6 Connect the 1 1 2 in outlet pipe to the sprinkler system by gluing in additional sect...

Страница 7: ...aces or chemicals ELECTRICAL SHOCK ALERT The pump must be properly grounded using the proper wire cable with ground ELECTRICAL SHOCK ALERT Always disconnect pump from electricity before performing any...

Страница 8: ...Connect green ground wire to green grounding screw Re install rear motor cover to pump To change from 230 V to 115 V 6 The motor of pump is dual voltage and can run on either 115 volts or 230 volts In...

Страница 9: ...and continue adding water to pump cavity until water comes out of the open outlet pipe at the open union 5 Wait 10 minutes to see if water level drops below the pipe tee If level drops check foot val...

Страница 10: ...wise to remove from shaft 4 Use a screwdriver to remove the rotary seal B Pry the ceramic seal and rubber gasket from the recess of the mounting bracket Fig 1 CAUTION Be careful not to damage the moto...

Страница 11: ...ak in inlet line 1 Repair or replace inlet line Use thread tape and pipe sealing compound 2 Vertical lift too high 2 Reduce vertical lift install foot valve and prime 3 Insufficient inlet pressure or...

Страница 12: ...placement Part Kits 1 1 1 1 1 1 Standard hardware item NOTE Motor assembly not available as a replacement part PRODUCT SPECIFICATIONS Model HP Suction Lift Ft Discharge Pressure PSI Shut Off Pressure...