background image

6

© Copyright 2021. All rights reserved.

PUMP INSTALLATION FOR WELL AND SURFACE WATER

1.  Mount pump on a solid foundation as close to 

the water source as possible. 

  CAUTION:  

Support the 2 in. inlet 

pipe from the well or lake to the inlet port 

to prevent sagging. Sagging will create air 

pockets within the pipe that will prevent the 

pump from priming and operating correctly.

2.  Glue female 2 in. union to the end of inlet 

pipe leading from the water source.

3.  Connect the 2 in. union together to complete 

the inlet line to the pump.

4.  Glue a 6 in. piece of 1-1/2 in. pipe to the 

female portion of the 1-1/2 in. union.

5.  Glue 1-1/2 in. ball valve to the other end of 

the 6 in. piece of pipe.

6.  Connect the 1-1/2 in. outlet pipe to the 

sprinkler system by gluing in additional 

sections of pipe as needed.

7. 

Connect union to ensure proper fit. Do not 

tighten until after priming.

  CAUTION: 

Do not glue union together.

Water Level

Discharge to 

Sprinkler System

Well Seal

100 PSI

Pressure 

Gauge

Priming Plug

Union

Ball

Valve

Outlet 

Pipe

Inlet

Pipe

Well

Union

Water 

Level

Outlet Pipe

Inlet

Pipe

2 in. 

Female 

Union

Fig 2

Fig 1

Water 

Level

Outlet Pipe

Inlet

Pipe

2 in. 

Union

1-1/2 in.

Union

Fig 4

Fig 3

Ball Valve

IL1123

Outlet Pipe

Inlet

Pipe

Discharge to 

Sprinkler System

Fig 6

Fig 5

IL1124

Outlet Pipe

Inlet

Pipe

Discharge to 

Sprinkler System

Fig 7

Содержание BPUMP1-5HP

Страница 1: ...WARNING ELECTRICAL SHOCK ALERT Follow all local electrical and safety codes as well as the National Electrical Code NEC and the Occupational Safety and Health Act OSHA ELECTRICAL SHOCK ALERT Replace...

Страница 2: ...not included 1 Priming Plug with Pressure Gauge Used instead of a priming plug alone Helps determine if the pump is primed indicates if the pump is operating properly and what kind of pressure is in...

Страница 3: ...e water as long as the pump is within 25 vertical feet of the water source Horizontal Distance The horizontal distance is the horizontal measurement between the pump inlet and the water source This di...

Страница 4: ...op of the pump 2 Glue a 6 in piece of 1 1 2 in pipe into the adaptor 3 Glue a 1 1 2 in tee to the pipe 4 Glue a 1 1 2 in slip x 1 1 4 in adaptor to the top opening of the 1 1 2 in tee 5 Thread in a 1...

Страница 5: ...n in the well 14 Glue a 90 elbow when the inlet pipe is in line with the inlet port of the pump For Surface Water Installations For surface water installations follow steps 11 and 12 above and then 15...

Страница 6: ...o the female portion of the 1 1 2 in union 5 Glue 1 1 2 in ball valve to the other end of the 6 in piece of pipe 6 Connect the 1 1 2 in outlet pipe to the sprinkler system by gluing in additional sect...

Страница 7: ...aces or chemicals ELECTRICAL SHOCK ALERT The pump must be properly grounded using the proper wire cable with ground ELECTRICAL SHOCK ALERT Always disconnect pump from electricity before performing any...

Страница 8: ...Connect green ground wire to green grounding screw Re install rear motor cover to pump To change from 230 V to 115 V 6 The motor of pump is dual voltage and can run on either 115 volts or 230 volts In...

Страница 9: ...and continue adding water to pump cavity until water comes out of the open outlet pipe at the open union 5 Wait 10 minutes to see if water level drops below the pipe tee If level drops check foot val...

Страница 10: ...wise to remove from shaft 4 Use a screwdriver to remove the rotary seal B Pry the ceramic seal and rubber gasket from the recess of the mounting bracket Fig 1 CAUTION Be careful not to damage the moto...

Страница 11: ...ak in inlet line 1 Repair or replace inlet line Use thread tape and pipe sealing compound 2 Vertical lift too high 2 Reduce vertical lift install foot valve and prime 3 Insufficient inlet pressure or...

Страница 12: ...placement Part Kits 1 1 1 1 1 1 Standard hardware item NOTE Motor assembly not available as a replacement part PRODUCT SPECIFICATIONS Model HP Suction Lift Ft Discharge Pressure PSI Shut Off Pressure...

Отзывы: