• LVM events
Level
Type
Description
Info
VG Created OK
Info: VG <name> has been created.
Warning
VG Created Fail
Warning: Fail to create VG <name>.
Info
VG Deleted
Info: VG <name> has been deleted.
Info
UDV Created OK
Info: UDV <name> has been created.
Warning
UDV Created Fail
Warning: Fail to create UDV <name>.
Info
UDV Deleted
Info: UDV <name> has been deleted.
Info
UDV Attached OK
Info: UDV <name> has been LUN-attached.
Warning
UDV Attached Fail
Warning: Fail to attach LUN to UDV <name>.
Info
UDV Detached OK
Info: UDV <name> has been detached.
Warning
UDV Detached Fail
Warning: Fail to detach LUN from Bus <number> SCSI_ID
<number> LUN <number>.
Info
UDV_OP Rebuild Started
Info: UDV <name> starts rebuilding.
Info
UDV_OP Rebuild Finished
Info: UDV <name> completes rebuilding.
Warning
UDV_OP Rebuild Fail
Warning: Fail to complete UDV <name> rebuilding.
Info
UDV_OP Migrate Started
Info: UDV <name> starts migration.
Info
UDV_OP Migrate Finished
Info: UDV <name> completes migration.
Warning
UDV_OP Migrate Failed
Warning: Fail to complete UDV <name> migration.
Warning
VG Degraded
Warning: VG <name> is under degraded mode.
Warning
UDV Degraded
Warning: UDV <name> is under degraded mode.
Info
UDV Init OK
Info: UDV <name> completes the initialization.
Warning
UDV_OP Stop Initialization
Warning: Fail to complete UDV <name> initialization.
Warning
UDV IO Fault
Error: IO failure for stripe number <number> in UDV
<name>.
Warning
VG Failed
Error: Fail to access VG <name>.
Warning
UDV Failed
Error: Fail to access UDV <name>.
Warning
Global CV Adjustment Failed
Error: Fail to adjust the size of the global cache.
Info
Global Cache
Info: The global cache is OK.
Error
Global CV Creation Failed
Error: Fail to create the global cache.
Info
UDV Rename
Info: UDV <name> has been renamed as <name>.
Info
VG Rename
Info: VG <name> has been renamed as <name>.
Info
Set VG Dedicated Spare Disks
Info: Assign Disk <slot> to be VG <name> dedicated spare
disk.
Info
Set Global Disks
Info: Assign Disk <slot> to the Global Spare Disks.
Info
UDV Read-Only
Info: UDV <name> is a read-only volume.
Info
WRBK Cache Policy
Info: Use the write-back cache policy for UDV <name>.
Info
WRTHRU Cache Policy
Info: Use the write-through cache policy for UDV <name>.
Info
High priority UDV
Info: UDV <name> is set to high priority.
Info
Mid Priority UDV
Info: UDV <name> is set to mid priority.
Info
Low Priority UDV
Info: UDV <name> is set to low priority.