background image

RCS11 1:1 Redundancy Switch

   Installation

TM061 Rev. 1.3

Page 2-3

Содержание RCS11

Страница 1: ...y form without the expressed written approval of Radyne Corporation is strictly prohibited This manual may not in whole or in part be copied reproduced translated or reduced to any electronic or magne...

Страница 2: ......

Страница 3: ...ting instructions provided by Radyne lack of routine care and maintenance as indicated in any operating maintenance instructions or failure to use or take any proper precautions under the circumstance...

Страница 4: ...37 9620 Fax 602 437 4811 Any product returned to Radyne for examination must be sent prepaid via the means of transportation indicated as acceptable to Radyne Return Authorization Number must be clear...

Страница 5: ......

Страница 6: ...r omissions that may pertain to the material herein is assumed Radyne Corporation makes no commitment to update nor to keep current the information contained in this document Radyne Corporation assume...

Страница 7: ...tems 2 1 2 1 2 In Case of Shipping Damage 2 1 2 1 3 Test Data Sheet 2 1 2 2 Site Considerations 2 1 2 2 1 Power Sources 2 1 2 3 Rack Mounting 2 2 2 4 Configuring the System 2 2 2 5 RCS11 Rear Panel Co...

Страница 8: ...ersal Interface Module UIM Connectors 2 23 2 12 Initial RCS11 Configuration 2 30 3 1 Operating Procedures 3 1 3 1 1 Configuring the RCS11 3 1 3 1 1 1 Manual Mode 3 1 3 1 1 2 Auto Mode 3 1 3 1 1 3 Powe...

Страница 9: ...s 5 1 5 2 RCS11 General Operation 5 1 5 2 1 Signals 5 1 5 2 2 Backup 5 1 5 2 3 Fail safe 5 2 5 2 4 Fault Relays 5 2 Appendix A RCS11 Technical Specifications A 1 Appendix B RCS11 Remote Communications...

Страница 10: ......

Страница 11: ...lly familiar with the operation of the individual Satellite Modems Modulators and or Demodulators that will be connected to the Switch Refer to Figure 1 1 for a pictorial representation of the RCS11 f...

Страница 12: ...defines a procedure which must be followed precisely in order to ensure the proper use of the equipment WARNING A WARNING identifies and also defines a procedure which requires mandatory compliance i...

Страница 13: ...RCS11 1 1 Redundancy Switch Description TM061 Rev 1 3 Page 1 3...

Страница 14: ......

Страница 15: ...ter is responsible for any damage caused during shipping Radyne Corporation should also be contacted Damage as a result of transport is not covered under the Radyne Corporation Warranty Refer to the W...

Страница 16: ...m of six inches of clearance must be provided at the sides and rear of the units In addition the RCS11 requires a minimum of 1 3 4 inches 1U of clearance on top of the unit If the Switch is mounted on...

Страница 17: ...RCS11 1 1 Redundancy Switch Installation TM061 Rev 1 3 Page 2 3...

Страница 18: ...Installation RCS11 1 1 Redundancy Switch Page 2 4 TM061 Rev 1 3...

Страница 19: ...RCS11 1 1 Redundancy Switch Installation TM061 Rev 1 3 Page 2 5...

Страница 20: ...Installation RCS11 1 1 Redundancy Switch Page 2 6 TM061 Rev 1 3...

Страница 21: ...r Panel Connectors Connector ID Nomenclature Description J1 Faults 9 Pin D Female Subconnector J2 Remote 9 Pin D Female Subconnector J3 Tx B 70 MHz IF IN from Modem B J4 Tx Out 70 MHz IF OUT to Tx RF...

Страница 22: ...on at 9 Pin D Female Subconnector J10 Terrestrial Data Sync RS422 37 Pin D Terrestrial Data Connector J11 Data B Sync RS422 37 Pin D Data Connector B J18 ES ES A ES to ES A channel connection at 9 Pin...

Страница 23: ...k B Output 27 CTS B Output 29 Data Mode B Output 30 DTR B Input 31 Receive Ready B Output 33 NC 35 Terminal Timing B Input Table 2 6 J7 Modem A J11 Modem B RS422 Data Interface Modem A and Modem B Con...

Страница 24: ...B Input 33 Demod Fault Alarm OC TTL Input 35 Terminal Timing B Output Table 2 7 J9 Terrestrial ES ES Channel Connection 9 Pin Female D Pin Signal Name Description 1 RXD B Receive Data B 6 DSR Date Se...

Страница 25: ...J9 Terrestrial ES ES ES to ES channel connection at 9 Pin D Female Subconnector J10 Terrestrial Data Sync RS232 25 Pin D Terrestrial Data Connector J11 Data B Sync RS232 25 Pin D Data Connector B J18...

Страница 26: ...ut 5 CTS A Output 6 DSR A Output 8 DCD A Output 15 ST A Output 17 RT A Output 19 EXT FIFO CLK A Input 20 DTR A Input 23 Demod Fault Alarm TTL OC Input 24 TT A Input 25 Mod Fault Alarm TTL OC Input No...

Страница 27: ...D2400 Sync V 35 Interface Rear Panel Connectors Table 2 14 RCS11 Rear Panel Connectors DMD2400 SYNC V 35 Configuration Connector ID Nomenclature Description J7 Data A V 35 25 Pin D Data Connector A J9...

Страница 28: ...tput 16 RD B RD Output 4 RTS Input 5 CTS Output 6 DSR Output 8 CD Output 21 Ext FIFO Clock B Input 19 Ext FIFO Clock A Input 20 DTR Input Table 2 16 J7 J11 V 35 Data Interface Modem A Modem B 25 Pin D...

Страница 29: ...Female D Pin Signal Name Description 1 RXD B Receive Data B 6 DSR Date Set Ready 2 RXD A Receive Data A 7 RTS Request to Send Pin 7 8 tied together 3 TXD A Transmit Data A 8 CTS Clear to Send 4 TXD B...

Страница 30: ...restrial Data RS 449 RS 422 37 Pin D Terrestrial Data Connector J11 Data B RS 449 RS 422 37 Pin D Data Connector B Table 2 20 J10 Terrestrial Data Interface Connector RS 449 RS 422 Pin Assignment Pin...

Страница 31: ...ignment Pin Signal Name Direction 1 Shield GND 4 Send Data SD A Output 5 Serial Clock Transmit SCT A Input 7 Ready To Send RTS A Input 9 CTS A Input 11 Data Mode DM A Input 14 Mod Fault Alarm OC TTL I...

Страница 32: ...A J10 Terrestrial Data RS422 Parallel 25 Pin D Terrestrial Data Connector J11 Data B RS422 Parallel 25 Pin D Data Connector B J18 Fault A TTL OC Fault Input 9 Pin D Female Connector J19 Fault B TTL OC...

Страница 33: ...D7 Input 25 D7 Input 13 Not Connected Table 2 24 J7 J11 Mod A Mod B Radyne RS 422 Parallel 25 Pin Female Optional Pin Signal Name Direction 1 OUTCLK Input 14 OUTCLK Input 2 CLK Output 15 CLK Output 3...

Страница 34: ...el Connections Table 2 26 RCS11 Rear Panel Connectors DVB3000 DVB Parallel Interface Configuration Connector ID Nomenclature Description J7 Data A RS422 Parallel 25 Pin D Data Connector A J10 Terrestr...

Страница 35: ...t 13 Cable Shield Input 14 Clock Input 15 System GND Ground 16 D7 Input 17 D6 Input 18 D5 Input 19 D4 Input 20 D3 Input 21 D2 Input 22 D1 Input 23 D0 Input 24 DVALID Input 25 SYNC Input Table 2 28 J7...

Страница 36: ...Output 18 D5 Output 19 D4 Output 20 D3 Output 21 D2 Output 22 D1 Output 23 D0 Output 24 DVALID Output 25 SYNC Output Table 2 29 J18 Fault A and J19 Fault B Connection 9 Pin Female D Connector Pin Sign...

Страница 37: ...the RCS11 Universal Interface Module J26 RD RECEIVE DATA J26 is the unbalanced Receive Data RD BNC connector located on the RCS11 Universal Interface Module J8 SYNC DATA J8 is the 37 pin Female synchr...

Страница 38: ...B Terminal Timing B Input 1 19 20 37 GND Signal Ground J7 G 703 BALANCED Table 2 31 below lists the pinouts and signal definitions for the G 703 Balanced 15 pin connector Table 2 32 J20 G 703 Balanced...

Страница 39: ...Out 2 Normally Closed 9 DDO A RT A G 703 Drop Data Out A Synchronous Data Receive Timing Output A Output 10 ESCBWO 3C IDR ESC Backward Alarm Output 3 Common 11 IDO A RD A G 703 Insert Data Out A Synch...

Страница 40: ...nput 36 SYNC SD B Synchronous Data Send Data Input B Input 37 ESCBWO 1 NC IDR ESC Backward Alarm Out 1 Normally Closed 38 G703B IDI B G 703 Insert Data Input B 39 SYNC ST B Synchronous Data Send Timin...

Страница 41: ...Open 63 TXO B IBS Transmit Octet Input B Input 64 SYNC DM B Synchronous Data Data Mode Out B Output 65 SYNC CS B Synchronous Data Clear to Send B Input 66 RXO B IBS Receive Octet Output B Output 67 S...

Страница 42: ...O 4NC Backward Alarm Out 4 NC 22 ESCBWI 1 Backward Alarm In 1 Input 23 ESCBWI 3 Backward Alarm In 3 Input 24 NC 25 NC J15 ESC 8K DATA INTERFACE Table 2 35 J15 ESC 8K Data Interface 15 Pin Female D Pin...

Страница 43: ...2 ESCAUDRX 1A Rx Audio 1A Output 3 GND 4 ESCAUDTX 2B Tx Audio 2B Input 5 ESCAUDRX 2A Rx Audio 2A Output 6 ESCAUDTX 1B Tx Audio 1B Input 7 ESCAUDRX 1B Rx Audio 1B Output 8 ESCAUDTX 2A Tx Audio 2A Input...

Страница 44: ...Power 2 Green LEDs should illuminate If there is a fault with either one of the power supplies the appropriate green LED will not illuminate Refer to Section 4 Basic Troubleshooting and Maintenance fo...

Страница 45: ...nline The Green LED should illuminate The RCS11 should 3 1 1 1 Manual Mode To manually select which MOD or DEMOD is to be placed online simultaneously depress the ENABLE pushbutton and the appropriate...

Страница 46: ...Manual Mode ENABLE Pushbutton Enables Front Panel controls to function SELECT AUTO Pushbutton Allows the operator to select Automatic Mode of operation Demodulator Controls and Indicators Online LED I...

Страница 47: ...RCS11 1 1 Redundancy Switch Operation TM061 Rev 1 3 Page 3 3...

Страница 48: ......

Страница 49: ...ING High voltage is present on the power supply heat sinks when the power supply is energized Use extreme caution when removing the RCS11 top cover when the unit is powered up Do not touch the top cov...

Страница 50: ...s Memory RAM failure in the Switch A loss of Carrier Detect on a Demodulator Channel where this attribute is monitored A loss of Terrestrial Input Clock on a Channel where this attribute is monitored...

Страница 51: ...ssor 5 1 2 Front Panel Board The Front Panel Board contains the LED indicators and the pushbutton switches needed to control and operate the RCS11 5 1 3 Redundant Power Supplies The 1 1 Switch comes e...

Страница 52: ...lay switches to a faulted state If Power Supply 1 and Power Supply 2 simultaneously fail the switching circuitry in the RCS11 reverts back to Modem A and the Switch Fault Relay switches to a faulted s...

Страница 53: ...itch Technical Specifications TM061 Rev 1 3 A 1 Appendix A RCS11 1 1 Redundancy Switch Technical Specifications A 1 Introduction This section defines the technical performance parameters for the RCS11...

Страница 54: ...Delay Time 1 sec IF Switching Coaxial 75 Ohm 50 Ohm optional 20 dB return loss Monitor and Control RS232 485 Terminal Mode Parameters Monitored Mode Mod Demod Modem Power Supply Status Internal Switch...

Страница 55: ...1 3 A 3 Power and Environmental Prime Power 100 240 Vac 50 60 Hz 40 Watts One Bank Operating Temp 0 to 50 degrees C 95 humidity non condensing Storage Temp 20 to 70 degrees C 99 humidity non condensi...

Страница 56: ...Appendix C RCS11 DIP Switch Configuration Tables...

Страница 57: ...or future expansion and should be left in the off position Mod Dmd Off Off Dmd Off On Mod On Off Modem On On Baud Rate S3 8 S3 7 9600 Off Off 4800 Off On 2400 On Off 1200 On On Soft On On Address S3 6...

Страница 58: ...On Off 55 Off On Off On On On 56 Off On On Off Off Off 57 Off On On Off Off On 58 Off On On Off On Off 59 Off On On Off On On 60 Off On On On Off Off 61 Off On On On Off On 62 Off On On On On Off 63...

Страница 59: ...Off On Off 91 On On On Off On On 92 On On On On Off Off 93 On On On On Off On 94 On On On On On Off Soft On On On On On On RS232 Driver S4 8 S4 7 S4 6 S4 5 S4 4 S4 3 S4 2 S4 1 RS232 Off On Off On Off...

Страница 60: ...4...