![Radyne RCS11 Скачать руководство пользователя страница 57](http://html1.mh-extra.com/html/radyne/rcs11/rcs11_installation-and-operation-manual_3364032057.webp)
RCS11
Configuration
How to use this table
All reserved switches should be left in the off position.
Select 'Soft' setting to allow changes in terminal mode.
Select <all others> for any setting that doesn't seem to apply.
Config
S2-2
S2-1
S2-8 .. S2-3 Are reserved for future
expansion and should be left in the
off position
Mod/Dmd
Off
Off
Dmd
Off
On
Mod
On
Off
Modem
On
On
Baud Rate
S3-8
S3-7
9600
Off
Off
4800
Off
On
2400
On
Off
1200
On
On
Soft
On
On
Address
S3-6
S3-5
S3-4
S3-3
S3-2
S3-1
32
Off
Off
Off
Off
Off
Off
33
Off
Off
Off
Off
Off
On
34
Off
Off
Off
Off
On
Off
35
Off
Off
Off
Off
On
On
36
Off
Off
Off
On
Off
Off
37
Off
Off
Off
On
Off
On
38
Off
Off
Off
On
On
Off
39
Off
Off
Off
On
On
On
40
Off
Off
On
Off
Off
Off
Содержание RCS11
Страница 2: ......
Страница 5: ......
Страница 10: ......
Страница 13: ...RCS11 1 1 Redundancy Switch Description TM061 Rev 1 3 Page 1 3...
Страница 14: ......
Страница 17: ...RCS11 1 1 Redundancy Switch Installation TM061 Rev 1 3 Page 2 3...
Страница 18: ...Installation RCS11 1 1 Redundancy Switch Page 2 4 TM061 Rev 1 3...
Страница 19: ...RCS11 1 1 Redundancy Switch Installation TM061 Rev 1 3 Page 2 5...
Страница 20: ...Installation RCS11 1 1 Redundancy Switch Page 2 6 TM061 Rev 1 3...
Страница 47: ...RCS11 1 1 Redundancy Switch Operation TM061 Rev 1 3 Page 3 3...
Страница 48: ......
Страница 56: ...Appendix C RCS11 DIP Switch Configuration Tables...
Страница 60: ...4...