1. INTENDED USE 

 

PUE  H315  weighing  indicator  is  intended

 

to  be  a  part  of  construction  

of  industrial  scales  based  on  load  cells.  It  is  equipped  with  a  stainless  steel 
housing of high IP. Clear weighing result presentation is ensured due to a large 
display (LCD). 

 

Standard  indicator  features  one  RS232  interface  and  USB  connector  
for  connection  with  peripheral  devices  (printer,  computer,  etc.).  The  indicator 
can  be  optionally  equipped  with  an  internal  battery,  this  allows  its  operation  
in places where there is no access to the mains. 

 
 

2. WARRANTY CONDITIONS 

 

A.  RADWAG feels obliged to repair or exchange all elements that appear to 

be faulty by production or by construction.  

B.  Defining defects of unclear origin and means of their elimination can only 

be realized with assistance of manufacturer and user representatives. 

C.  RADWAG  does  not  bear  any  responsibility  for  damage  or  losses 

resulting  from  unauthorized  or  inadequate  performing  of  production  
or service processes. 

D.  The warranty does not cover: 

  mechanical  damage  caused  by  product  exploitation  other  than 

intended, damage of thermal and chemical origin, damage caused by 
lightning, overvoltage in the power network or other random event, 

  inappropriate cleaning habits. 

E.  Loss of warranty takes place if: 

  a repair is carried out outside RADWAG authorized service point, 

  service claims intrusion into mechanical or electronic construction by 

unauthorized people, 

  the device does not bear company protective stickers. 

F.  Warranty  conditions  outline  the  warranty  period  for  rechargeable 

batteries attached to the device for 12 months. 

G.  For detailed warranty conditions read the warranty certificate. 
H.  Contact with the central authorized service: +48 (48) 386 63 30. 

Содержание PUE H315

Страница 1: ......

Страница 2: ...2 SEPTEMBER 2021...

Страница 3: ...e immediately unplug the device from the mains Scales to be decommissioned must be decommissioned in accordance with valid legal regulations Do not let battery discharge in case of prolonged storage o...

Страница 4: ...ETUP 14 8 1 Access 14 8 2 Factory Parameters List 15 8 3 Device Defining 17 8 4 Factory Adjustment 18 8 4 1 External Adjustment Process 18 8 4 2 Start Mass Determination 18 8 4 3 Correction of Start M...

Страница 5: ...ized with assistance of manufacturer and user representatives C RADWAG does not bear any responsibility for damage or losses resulting from unauthorized or inadequate performing of production or servi...

Страница 6: ...of dishwashing detergent 3 2 Cleaning ABS Components To clean dry surfaces and avoid smudging use clean non colouring cloths made of cellulose or cotton You can use a solution of water and detergent s...

Страница 7: ...SB connector 5 RS232 1 connector 6 Universal socket or gland RS232 2 or RS485 or Ethernet or IN OUT 4 3 Pins Arrangement RS232 1 RS232 2 Pin1 NC Pin2 RxD Pin3 TxD Pin4 NC Pin5 GND Pin6 5VDC Pin7 NC Pi...

Страница 8: ...on key press to change the working mode Press to send the weighing result to a printer or computer Press to zero the scale Press to tare the scale Upon pressing keys combination functions of given key...

Страница 9: ...s with shield Max number of platforms 1 Multirange Yes RS232 1 M12 8P connector USB M12 4P connector Optional Equipment RS232 2 M12 8P connector RS485 M16 cable gland Ethernet M12 4P connector 4 20mA...

Страница 10: ...Pictogram displayed continuously Too low battery charge the scale is about to shut down Charge the battery immediately Blinking pictogram blink frequency ca 1 s Battery charge in progress The device i...

Страница 11: ...current parameter value Press to enter given submenu Press to modify given parameter Press to confirm modification Press to exit function remains unmodified Press to move one menu level up 6 1 Return...

Страница 12: ...oad cell socket Load cell signals NOTES REF SENSE JP3 not soldered REF SENSE JP4 not soldered IN OUTPUT IN OUTPUT 5V INPUT AGND INPUT 7 2 Connecting 4 Wire Load Cell Connect 4 wire load cell to the ma...

Страница 13: ...Cable Shield Platforms connected to indicators in metal housing via a cable only Platforms electrically connected to indicators metal housings e g pillars racks Load cells with internal shield connect...

Страница 14: ...h the weighing device off to do it press key Press and hold S1 switch located on the electronics board while holding the S1 switch press key to run the weighing device Access to factory setup switch W...

Страница 15: ...c RTC synchronisation 0 1 A ntE YES no US market metrological requirements activation 0 2 nnG Metrology 0 2 1 A d Converter s divisions 0 2 2 Uni g kg lb Adjustment unit 0 2 3 du1 0 0001 0 0002 0 0005...

Страница 16: ...mass control YES range from 10 to 10 of start mass no off 50 range from 50 to 50 of start mass dEF range declared in 0 2 G parameter 0 2 G rnt 10 90 Start mass range in 0 2 H Ldn no YES Digit marker...

Страница 17: ...parameters serial number weighing device type weighing range Procedure Enter factory setup P0 FAct Go to 0 1 Glob 0 1 1 duu submenu text Cont is displayed Press key text nr FAc is displayed next you s...

Страница 18: ...ighing pan with the required adjustment weight Press key adjustment starts After adjustment completion 0 3 1 CLE submenu is displayed automatically Exit to the home screen to do it press key repeatedl...

Страница 19: ...Correction Points Enter factory setup submenu P 0 FAct 0 4 Line 0 4 1 dSG text Cont is displayed Press key to confirm Text Pnt1 is displayed linearity connection point no 1 Press key window for enter...

Страница 20: ...ext linearity correction point to do it press key Correcting the linearity correction point no 2 is analogous In order to finish correcting linearity correction points press key 0 4 3 Cor submenu is d...

Страница 21: ...o be mounted inside the indicator It is equipped with optoisolated inputs and semiconductor outputs and enables free configuration of both the inputs and the outputs using indicator menu The indicator...

Страница 22: ...odule 9 1 2 I O Schematic Diagrams 4 inputs 4 outputs 9 1 3 Input Output Signals Overview INPUTS OUTPUTS Wire number Signal Wire number Signal 1 IN1 6 OUT1 2 IN2 7 OUT2 3 IN3 8 OUT3 4 IN4 9 OUT4 5 COM...

Страница 23: ...an additional cable gland through which 3 metre cable 2 x 0 25 mm2 is fed which cable is terminated with isolated wires 4 20mA 636R module 9 2 1 Technical Specifications Output resolution 16bit Linea...

Страница 24: ...nds the PUE H315 indicator functionality by RS485 interface The module is intended to be mounted inside the indicator The indicator s housing cover features an additional cable gland through which 3m...

Страница 25: ...over features an additional M12 4P D codded connector Ethernet standard RS485 635R module 9 4 1 Ethernet Pins Ethernet Pin1 RX Pin2 TX Pin3 RX Pin4 TX 9 5 Additional Modules Arrangement 635R board inc...

Страница 26: ...26 Exemplary assignment of modules on 634R board Additional modules arrangement 10 DIAGRAMS OF CONNECTION CABLES Indicator computer cable Indicator printer cable EPSON...

Страница 27: ...27 Indicator USB adapter cable...

Страница 28: ...28...