58
Manual
–
AlphaAir Freshbox 25 Basic
Reference pressure difference
in Pa
27
Specific input power at
reference volumetric flow in
W/m³/h
0,42
Type of ventilation control
(manual / time / central /
demand)
Demand
x-value (speed control factor)
2
inner leakage in %
3
external leakage in %
3,5
Annual power consumption JSV
per 100m² in kWh/a per
climate zone (cold, average,
warm)
1061
524
479
Annual heating energy savings
per 100m² (JEH) in kWh
primary energy/a per climate
zone (cold, average, warm)
7633
3902
1764