48
Manual
–
AlphaAir Freshbox 25 Basic
11
Troubleshooting
Malfunction
Possible cause / elimination
Device does not
work
No power, insufficient contact or wrong
polarity.
Please check whether the power supply
unit is supplying power, the polarity (+/-)
is connected correctly and the green LED
on the device board is lit.
Device cannot be
operated
Probably the child lock is activated.
It can be deactivated again by pressing
the left power button for approx. 6
seconds (3 beeps).
A motor does not
run or the unit
does not respond
to button presses
One plug has no contact.
Check which plug has come loose either at
the circuit board or at the motor sockets
and press it tight again.
The air flow rate is
too low
Filter or grille of the tube shutters
clogged.
Clean or replace the two filter mats. The
grille of the outer tube orifice may have
become clogged with dust that has been
sucked in and needs to be cleaned.