![RadonTec AlphaAir Freshbox 25 Скачать руководство пользователя страница 25](http://html.mh-extra.com/html/radontec/alphaair-freshbox-25/alphaair-freshbox-25_manual_780757025.webp)
25
Manual
–
AlphaAir Freshbox 25 Basic
EXTERNAL CONTROL OF THE TIMER FUNCTION
Since software version 13080000 (update available for free in
RadonShop), the unit can be remotely controlled by external
buttons, switches or relays. This function is useful if, for
example, the unit is not directly accessible in the room, it is to
be controlled via the relay of a light switch (toilet) or motion
detector (smoking room), or the occupants wish to send
several units into intensive ventilation at the same time, e.g.
when leaving the building. In addition, many other applications
are possible.
[Fig. 3: Electronics board]
On figure no. 3 the green terminal strip [4] can be seen. If the
contact between pin 1+2 is closed, it has the same function as
if the timer button is pressed on the device, which is freely
programmable in power and duration.
Thereby there are the following application possibilities:
1.
If the contact is closed >0.5 but <3 seconds, the device
recognizes that a button has been operated and per
button press the interval is extended by one interval
Содержание AlphaAir Freshbox 25