EXM-31 Hardware Reference
Page 40
4
4
S2 Escape
Character
S2 holds the decimal value of the ASCII character used as the escape character. The
default value corresponds to an ASCII +. A value over 127 disable the escape
process, i.e., no escape character will be recognized.
Range: 0 - 255
Default: 043
Units: ASCII
S3
Carriage Return <CR> Character
Sets the command line and result code terminator character. Pertains to asynchronous
operation only.
Range: 0 - 127, ASCII decimal
Default: 013 (carriage return)
Units: ASCII
S4
Line Feed <LF> Character
Sets the character recognized as a line feed. Pertains to asynchronous operation only.
The line feed control character is output after the carriage return control character if
verbose result codes are used.
Range: 0 - 127, ASCII character
Default: 010 (Line Feed)
Units: ASCII
S5
Back Space <BS> Character
Sets the character recognized as a backspace. Pertains to asynchronous operation
only. The modem will not recognize the Backspace character if it is set to a value that
is greater than 32 ASCII. This character can be used to edit a command line. When
the echo command is enabled, the modem echoes back to the local DTE the
Backspace character, an ASCII space character, and a second backspace character;
this means a total of three characters are transmitted each time the modem processes
the Backspace character.