K2015 Alarm Modules and Relay Outputs
_______________________________
K2100/K1100 User Guide
_______________________________
74-07069-000-B 3/94
Page 63
© 1994 Radionics, Inc.
System Events
Below is a table showing the types of event and their code number, that can be assigned
to a relay.
System Event
Relay
Code
Notes
No Response
0
Door Alarm on any door
1
Note 1
Door Left Open on any door
2
Note 2
Enclosure Tamper
3
Door 1 Open
4
Note 3
Door 2 Open
5
"
Door 3 Open
6
"
Door 4 Open
7
"
Door 1 Left Open
8
Note 4
Door 2 Left Open
9
"
Door 3 Left Open
10
"
Door 4 Left open
11
"
Door 1 Alarm
12
Note 5
Door 2 Alarm
13
"
Door 3 Alarm
14
"
Door 4 Alarm
15
"
Notes:
1. An alarm event, i.e. unauthorized access, cable tamper, at
any
of the 4 doors
on the door controller will activate a relay given this code. The relay will not be
deactivated until
all
such alarms are cleared. This is the same as the default
action given to relay 1 if not programmed otherwise.
2. This code will activate a relay if
any
of the 4 doors on the door controller are
left open, it will be deactivated when all the doors are closed. This is the same
as the default action given to relay 3 if not programmed otherwise.
3. These codes will activate a relay if the particular door is opened, for whatever
reason, it will deactivate when the door is closed.
4. These codes will activate a relay if the particular door is left open, it will
deactivate when the door is closed.
5. These codes will activate a relay if the particular door has an alarm event, i.e.
unauthorized access or cable tamper, it will deactivate when the alarm is
cleared.
Time Profiles
A relay can be made to operate with a Time Profile. When the Time Profile is active the
relay will be set. Examples may the use of external lighting, switching heating or ventilation
systems etc.