background image

16

17

Turning on the Scanner

The squelch and attenuator control scanner 
sensitivity. If squelch is set too low, the scanner may 
stop on noise or silence. 

Note: 

Make sure the scanner’s antenna is connected 

before you turn it on.

1. 

Turn the 

SQUELCH 

knob

 

to about mid-position.

2. 

Turn the 

VOLUME 

knob to turn on the radio.

3. 

Turn 

SQUELCH

 down (counterclockwise) until 

you hear noise.

4. 

Turn 

SQUELCH

 up (clockwise) a little past where 

the noise stops. The higher the squelch is set, 
the stronger the signal required to break the 
squelch.

Setting the Battery Type

Setting the battery type is necessary for low battery 
detection and to enable battery charging. By default, 
your new scanner is configured to use alkaline 
batteries. 

If you are using rechargeable batteries:

1. 

Press the 

PGM

 key.

2. 

Press the 

GLOB

 softkey.

3. 

Use the 4-direction keypad to select the 

Battery

 setting and set your battery type.

4. 

Press the 

SAVE

 softkey.

Understanding the Display Icons

Your PRO-651 features a high contrast, backlit 
Liquid Crystal Display (LCD).

The scanner uses the following top row of icons:

F

The Function Key ( FUNC) has been pressed. 

This acts as a “Shift” key. 

T

The scanner is currently receiving trunking 

control channel data.

G

The attenuator is set for Global mode.

A

The attenuator is currently active.

S

The radio’s squelch circuit is open.

Signal meter indicating signal strength.

Battery status indicator. Flashes when 

charging, solid when batteries are weak, 

and flashes quickly when battery failure is 

imminent. 

NOTE:

 This indicates if the battery charger 

circuit is active, but does not indicate charging. 

Batteries will only charge if the yellow battery 

holder is in use.

Indicate scan or search direction.

F

T

GA

    

S

   

  

Srch  

Limit  

ZD

FM  

 

  154.935000

154.00   155.00
FrL/O  

Mode 

Stor

Содержание PRO-651

Страница 1: ...shack com Esta gu a del usuario est disponible en espa ol en www radioshack com Digital TruNking Handheld Radio Scanner Thank you for purchasing your Handheld Radio Scanner from RadioShack Please read...

Страница 2: ...Scanning 28 Priority Scan 30 Favorites Scan List 31 Object Lockout 32 Multi Site Mode Motorola and P25 34 Home Repeater AutoMove LTR 35 Searching 36 Limit Search Object LMIT 38 Service Search Object S...

Страница 3: ...Battery Holder Rechargeable Battery Holder Introduction Scanning technology has changed dramatically over the years The Pro 651 scanner with Object Oriented User Interface is designed to help hobbyis...

Страница 4: ...ourage responsible legal scanner use In some areas mobile use of this scanner is unlawful or requires a permit Check the laws in your area It is also illegal in many areas to interfere with the duties...

Страница 5: ...vinganoutdoorantenna Iftheantennastartsto fall letitgo Itcouldcontactoverheadpowerlines Ifthe antennatouchesapowerline touchingtheantenna mast cable orguywirescancauseelectrocutionand death Callthepow...

Страница 6: ...Notes Always dispose of old batteries promptly and properly Do not bury or burn them Use only fresh batteries of the required size and recommended type Do not mix old and new batteries different type...

Страница 7: ...e back of radio and slide the belt clip upwards To attach the belt clip slide it down into the belt clip receptacle on the back of the radio until it locks in place Headphones and Speakers You can plu...

Страница 8: ...II TUNE Direct tuning of any valid frequency FUNC TUNE loads the most recently scanned frequency SRCH Search Mode for service and conventional frequencies ATT Attenuator On Off FUNC ATT sets Global At...

Страница 9: ...2 Press the GLOB softkey 3 Use the 4 direction keypad to select the Battery setting and set your battery type 4 Press the SAVE softkey Understanding the Display Icons Your PRO 651 features a high con...

Страница 10: ...ch is available at your local RadioShack store The cable lets you use software provided by RadioReference com and their constantly updated database to program your new scanner quickly and easily Radio...

Страница 11: ...ource scanner press PGM 4 Press the GLOB softkey 5 Use the 4 direction keypad to locate the Clone Send option 6 Press SEL to transfer data NOTE Working memory and global settings are transferred but n...

Страница 12: ...8 S 74 s 7 F 4 0 F 9 T 81 t 8 F 1 0 F 0 U 82 u 8 F 2 V 83 v 8 F 3 W 91 w 9 F 1 X 92 x 9 F 2 Y 93 y 9 F 3 Z 94 z 9 F 4 Use the 4 direction keypad to move the cursor Press FUNC and the 4 direction keyp...

Страница 13: ...organize your scan lists geographically assigning objects for your location in one list and objects for other locations in different lists You can organize your scan lists by trunking system assignin...

Страница 14: ...y press MAN to begin monitoring the object To find objects that are locked out 1 Press PGM 2 Press the EDIT softkey 3 Press the FIND softkey 4 Press the L Out softkey 5 Press the NEXT softkey to find...

Страница 15: ...n the keypad For 11 20 press FUNC and then the second number FUNC 3 13 When the scanner recieves a transmission the object infomation apears on the screen 3 To pause the scanner on an active object pr...

Страница 16: ...Priority setting directly during programming G Scanning 1 3 7 PRI Priority On Priority Off G Scanning 1 3 7 pri To activate Priority Scan Mode While the radio is scanning press FUNC and then press PR...

Страница 17: ...ess L OUT To apply permanent lockout press FUNC and then L OUT To lock out a talkgroup press the TGL O softkey Temporary Lockout G 04 0237 CONV plD FM 153 950000 FIRE CT 127 3 G 04 0237 CONV pLD FM 15...

Страница 18: ...ntrol channel in the list Roam The scanner will use only the best control channel You can adjust the Threshold values to improve performance 7 Press the SAVE softkey 8 Press the SAVE softkey again NOT...

Страница 19: ...requencies and press the Save softkey S Srch Limit ZD AM 26 500000 25 00 1 3 0 0 0 0 Lmts Mode Stor L i m i t S e a r c h FrLo 25 000000 FrHi 1300 000000 Save Exit Dflt To start a service search Press...

Страница 20: ...ncy Press the STOR softkey to create a new CONV object using the found frequency Change Setting Scroll LMIT Menu Reference Scan Lists Press SEL to assign the object to scan lists An asterisk indicates...

Страница 21: ...found frequency Change Setting Scroll SRVC Menu Reference Scan Lists Press SEL to assign the object to scan lists An asterisk indicates an assigned scan list SRVC Service Radio Services Public Safety...

Страница 22: ...frequency Press the STOR softkey to create a new CONV object using the found frequency Change Setting Scroll STLK Menu Reference Scan Lists Press SEL to assign the object to scan lists An asterisk in...

Страница 23: ...location codes can be found online at www nws noaa gov A list of event codes can be found online at www weather gov os eas_codes shtml SAME codes can include numbers and letters The standard text entr...

Страница 24: ...ings that if not set properly may adversely affect the performance of your radio We recommend caution when changing these settings NOTE Each parameter includes a Dflt softkey that restores the factory...

Страница 25: ...sh the LED OFF duration 1 250 x 10 mS LED BlinkOn When Alert LED is set to Flash the LED ON duration 1 250 x 10 mS GLOB Menu Reference Cont Pri Channels Number of priority CONV channels to check durin...

Страница 26: ...overwrite the existing data with new data 5 The scanner may prompt you for a name for the V Scanner The current name or Line 4 of the Welcome Screen appears If you change the name here it will not ov...

Страница 27: ...ENTER if APPROVE CLEAR to EXIT GLOB EEPROM area Initialized to defaults Press any key Initializing to Factory Defaults You can initialize the entire scanner to factory defaults This clears all program...

Страница 28: ...p available for each menu item when you program your scanner To access the help press FUNC and then SEL Press SEL again to exit the help screen Manual Programming Guide Sequence Function 1 Shortcut to...

Страница 29: ...d P25 Project 25 Squelch Code required Squelch Code Use Search to detect tone or code value for selected squelch type CONV Menu Cont L Out Permanent lockout status for the object Priority On or off LE...

Страница 30: ...nt L Out Permanent lockout status for the object Atten Attenuator applies 20 dB of attenuation Useful in areas with interference from strong signals Narrow FM Used by most 900 MHz analog systems Not u...

Страница 31: ...n lists An asterisk indicates an assigned scan list TSYS Select or define a TSYS object ID Digital address for the talkgroup or individual radio Wildcard Decimal hex or AFS depending on TSYS type Wild...

Страница 32: ...n the NS Scan List 1 Locate the NS list and use the 4 direction keypad to access the list 2 Select and object and press PGM 3 Press the EDIT softkey 4 Press the CURR softkey 5 Use the four direction k...

Страница 33: ...ations using flexible Scannable Object system Virtual Scanners 21 Virtual Scanner V Scanner folders Searches Seven preprogrammed dedicated service searches one dedicated limit search Programmable serv...

Страница 34: ...000 137 995 MHz in 5 kHz steps FM 138 000 143 9875 MHz in 12 5 kHz steps FM 144 000 147 995 MHz in 5 kHz steps FM 148 000 150 7875 MHz in 12 5 kHz steps FM 150 800 150 845 MHz in 5 kHz steps FM 150 8...

Страница 35: ...nd improvement without notice Maintenance Keep the scanner dry if it gets wet wipe it dry immediately Use and store the scanner only in normal temperature environments Handle the scanner carefully do...

Страница 36: ...the property of RadioShack Replaced parts and products are warranted for the remainder of the original warranty period You will be charged for repair or replacement of the product made after the expi...

Страница 37: ...2000651 Printed in Korea 06A14 2014 RadioShack Corporation All rights reserved RadioShack is a registered trademark used by RadioShack Corporation...

Отзывы: