Installation Manual
SYSTEM BOILER – Cod. 99951NA – November 2002
4
TYPE C WALL-MOUNTED
BOILERS
SEALED COMBUSTION
CIRCUIT:
Kit G.
Horizontal coaxial exhaust
flue system with 360° rotation.
It allows the flue exhaust and
the air intake directly to an
external wall. .
N.B.: To insert a bend in the
flue, reduce total flue length by
0.8 m.
Kit B.
Double exhaust/emission twin
flue system with 360° rotation.
It allows the flue exhaust into a
flue duct and the air intake
directly from an external wall.
N.B.: To insert a bend in the
flue, reduce total flue length by
1.5 m.
R
RETURN ¾”
G
GAS 1/2"
F
COLD WATER INLET 1/2"
A
HEATING FLOW ¾”
NOTE:
USE ORIGINAL RADIANT APPROVED FLUE KIT SYSTEMS, FLUE ACCESSORIES AND FLUE DIAPHRAGMS ONLY.
APPROVED RADIANT FLUE DIAPHRAGMS AND ADJUSTMENT TABLES ARE SUPPLIED WITH RADIANT ORIGINAL FLUE KIT
SYSTEMS.