Installation Manual 

SYSTEM BOILER  – Cod. 99951NA – November  2002

 

 

 

GENERAL INSTALLATION REQUIREMENTS 
 

GAS SAFETY 

 
It is the law that all gas appliances are installed by a CORGI registered installer (you can check this by contacting corgi on 01256.372200) in 
accordance with the regulations listed below.  Failure to install appliances correctly could lead to prosecution.  It is in your own interest and 
that of safety to ensure that the law is complied with.  Failure to have your appliance installed to comply with the installation instructions and 
the requirements listed below could invalidate your guarantee. 
 

RELATED DOCUMENTS 

The installation of the boiler must be in accordance with the relevant requirements of the Gas Safety regulations, Building regulations, I.E.E. 
regulations and the bylaws of the local water authority. 
It should be in accordance also with any relevant requirements of the local authority and the relevant recommendations of the following 
British Standard Codes of Practice: 
 
 

B.S 6400: 

1985  & B.S. 6891 : 1988. 

 

BS 5376: 

Selection and Installation of Gas Space Heating ( 1 and 2 family gases) 

 

 

Part 2:  Boilers of rated input not exceeding 60 Kw 

 

BS 5449: 

Central Heating for domestic premises 

 

 

Part 1:  Forced circulation Hot Water System 

 

CP 342: 

Centralised Hot Water Supply BS 6700 : 

1987 

 

 

Part 2:  Buildings other than individual 

 

BS 5440: 

Flues and air supply for Gas Appliances of rated input not exceeding 

 

 

60 Kw (1 and 2 family gases) 

  

Part 

1: 

Flues 

 

 

Part 2:  Air Supply 

 

BS 5446: 

1990:  Installation of Gas Hot Water supplies for domestic purposes 

 

GAS SUPPLY 

Service Pipes:  The local gas region should be consulted at the installation planning stage in order to establish the availability of supply of 
gas.  An existing service pipe must not be used without prior consultation with the local gas region. 
Meters:  A gas meter is connected to the service pipe by the local gas region or local gas region contractor. An existing meter should be 
checked to ensure that it is capable of passing an additional 3.4 m3/hr (125 ft/hr)  before the appliance is installed.  The meter outlet 
governor should ensure a nominal dynamic pressure of 20m Bar, (8 in wg) at the boiler.  Installation pipes should be fitted in accordance with 
BS6891.1988.  

Pipework that supplies the boiler must be a 22 mm. ininterrupted supply from meter to the isolation cock of the 

boiler.

 The complete installation must be tested for soundness as described in the above code, BS 6400: 1985 & BS6891. 

 
IMPORTANT:  BOTH THE USER AND THE MANUFACTURER RELY UPON THE INSTALLER, WHOSE JOB IS TO INSTALL THE BOILER 
AND CONNECT IT TO A CORRECTLY DESIGNED HEATING SYSTEM.  THE INSTALLER SHOULD ACQUAINT HIMSELF WITH THE 
CONTENTS OF THIS PUBLICATION AND THE RELEVANT BRITISH STANDARDS CONCERNING INSTALLATION REQUIREMENTS. 
 

LOCATION OF BOILER 

In siting the combination boiler, the following limitations MUST be observed: 
The position selected for installation should be within the building, and MUST allow  
adequate space for installation, servicing and operation of the combination boiler, and for air circulation around it. The boiler is not suitable 
for external installation. 
This position MUST also allow for a suitable flue termination to be made.  The boiler must be installed on a flat vertical wall which is capable 
of supporting the weight of the combination boiler, and any ancillary equipment. 
If  the boiler is to be fitted in a timber framed building it should be fitted in accordance with the British Gas publication "Guide for Gas 
Installations in Timber Frame Housing, Reference IGE/UP/6. If in doubt, advice must be sought from the local  region of British Gas. 
The boiler may be installed in any room or internal space, although particular attention is drawn to the requirements of the current I.E.E. 
Wiring Regulations, and in Scotland the electrical provisions of the Building Regulations applicable in Scotland, with respect to the 
installation of the boiler in a room or internal space containing a bath or shower. 
Where a room-sealed appliance is installed in a room containing a bath or shower, any electrical switch or appliance control utilising mains 
electricity must be so situated that it cannot be touched by a person using the bath or shower. 
A compartment used to enclose the combination boiler MUST be designed and constructed specifically for this purpose.  An existing 
cupboard, or compartment, may be used provided it is modified accordingly. 
Where installation will be in an unusual location, special procedures may be necessary.  BS 6798 gives detailed guidance on this aspect. 
For clearances to be made available for installation and servicing, see Sections 5.2.2. to 5.2.4. 

 
 
 
 

Содержание RS 30 E

Страница 1: ...Specification RADIANT BRUCIATORI S p A Montelabbate PU ITALY By Technical Department INSTALLATION AND MAINTENANCE MANUAL FOR GAS FIRED ONLY HEATING WALL HUNG BOILERS SYSTEM BOILERS Model RS 20 E RS 2...

Страница 2: ......

Страница 3: ...QUIREMENTS page 5 BOILER INSTALLATION page 7 ELECTRICAL CONNECTIONS page 9 15 16 BOILER CONTROL PANEL page 10 STARTING UP THE BOILER FOR THE FIRST TIME page 10 REGULATING THE GAS PRESSURE page 12 MULT...

Страница 4: ...an expansion vessel 2 WARNINGS REGARDING INSTALLATION Warranty expires 12 months from date of installation and in all cases no later than 18 months from date of construction First start up must be pe...

Страница 5: ...KCal h 9450 12900 14560 Kw 11 15 16 90 BTU hr 37498 51187 57774 Max working pressure heating bar 3 3 3 Max working pressure water bar 6 6 6 Min working pressure heating bar 0 3 0 3 0 3 Max heating tem...

Страница 6: ...60 rotation It allows the flue exhaust into a flue duct and the air intake directly from an external wall N B To insert a bend in the flue reduce total flue length by 1 5 m R RETURN G GAS 1 2 F COLD W...

Страница 7: ...tem with 360 rotation It allows the flue exhaust into a flue duct and the air intake directly from an external wall N B To insert a bend in the flue reduce total flue length by 1 5 m R RETURN G GAS 1...

Страница 8: ...1988 Pipework that supplies the boiler must be a 22 mm ininterrupted supply from meter to the isolation cock of the boiler The complete installation must be tested for soundness as described in the a...

Страница 9: ...ulted Where the lowest part of the terminal is fitted less than 2m 6 6ft above a balcony above ground or above a flat roof to which people have access the terminal MUST be protected by a purpose desig...

Страница 10: ...ary pipe connections WATER CONNECTIONS To facilitate installation the boiler is equipped with a fittings kit IMPORTANT Before connecting the heating system pipes carefully clean the system to prevent...

Страница 11: ...e temperature falls to 5 C Heating sensor and 4 C Hot water sensor and protects the boiler down to 2 C external temperature To protect the internal Radiators a room thermostat or remote control must b...

Страница 12: ...r screws on the housing and open the electrical control box by lifting the cover as shown in fig 1 E With the electrical control box now open make the following connections Connect the yellow green wi...

Страница 13: ...e gas cock and check the gas seals making sure the counter shows no sign of leaks in any case double check by using a soapy solution and eliminate all eventual leaks The checking procedure for the gas...

Страница 14: ...gnition procedure in any case wait 3 minutes before turning the boiler off and on again then try to ignite it once more calibrate the boiler after carrying out this operation return the panel to its c...

Страница 15: ...P1 MAX HEAT trimmer to the minimum heat by turning it counter clockwise regulate the minimum pressure by turning the P2 MIN GAS trimmer see the table below for calibration pressures on completion set...

Страница 16: ...for gas leaks each time gas connections are dismantled and reassembled d replace the gas setting plate that indicates the type of gas and nominal pressure for the boiler When converting the boiler to...

Страница 17: ...IRCULATING PUMP RSL 15 6 5 GAS VALVE VK4105 6 LT 6 EXPANSION VESSEL 7 3 BAR SAFETY VALVE 8 BURNER 13 R 9 BURNER 17 R 10 HEATING SENSOR 11 WATER PRESSURE SWITCH 12 WATER PRESSURE GAUGE 13 LIMIT THERMOS...

Страница 18: ...CLOCK ROOM THERMOSTAT SUMMER WINTER SWITCH TA E I ER EA OR IMPORTANT RESPECT LIVE NEUTRAL POLARITY 19 POWER SUPPLY TERMINAL BLOCK 16 Switch E I IG 18 17 N L M2 7 5 6 9 8 PAC blue black TF 1 2 black br...

Страница 19: ...10 R6 M7 RV C 35 M7 33 EV C3 RV D6 M7 32 26 LB M5 TL 8 7 6 5 4 3 1 2 24 M5 ROOM SEALED WIRING DIAGRAM RT LOW VOLTAGE CIRCUIT MAX HEAT MIN GAS T HEAT T SAN THERMOSTATS MODULATION BLOCK SPIA 1 BAR SPIA...

Страница 20: ...ption in the instruction manual for the boiler When dismantling the boilers casing be careful when removing the side panels after having removed the front panel the side panels are removed by undoing...

Страница 21: ...Installation Manual SYSTEM BOILER Cod 99951NA November 2002 18 SHORT LIST...

Страница 22: ...TA02B101 B1203 Technical Specification RADIANT BRUCIATORI S p A Montelabbate PU ITALY ENGLISH USER MANUAL Model RS 20 E 40 60 TYPE C ROOM SEALED Model RS 24 E 70 90 TYPE C ROOM SEALED...

Страница 23: ...the boiler in efficient and safe operating condition carefully follow the instructions listed below Have normal maintenance performed at least once a year by one of our authorised service centres a fe...

Страница 24: ......

Страница 25: ...LET HAVE BEEN CAREFULLY PREPARED BUT WE RESERVE THE RIGHT TO MAKE CHANGES AND IMPROVEMENTS IN OUR PRODUCTS WHITCH MAY AFFECT THE ACCURANCY OF THE INFORMATION CONTAINED IN THIS LEAFLET E OE ALL RIGHTS...

Страница 26: ......

Страница 27: ......

Страница 28: ......

Страница 29: ......

Отзывы: