MAINTENANCE INSTRUCTIONS
57
Regulating the Flow temperature in accordance with the outdoor temperature
The outdoor sensor has to be connected directly to circuit board SM30003. The sensor can thus be managed in
one of two ways:
•
In case of
RADIANTS
remote cont outdoor temperature sensor installation, the climatic compensation
curve is set by the remote itself (see remote control installation and operating manual).
•
In case of outdoor temperature sensor only installation, the climatic compensation curve is set using the central
heating control knob. As the knob (see fig. 2) is rotated, the numbers corresponding to the curve shown in
figure 1 are displayed
The factors governing the correction is reported in figure 1.
The selection of the compensation curve is determined by the maximum delivery temperature Tm and the minimum
outdoor temperature Te.
N.B. The y-axis values of the delivery temperature Tm refer to standard 80-30 °C appliances or 40-25 °C flo or-
mounted appliances. The type of appliance can be programmed using parameter 3 (see 5.1 “Parameter
programming”).
13
OUTDOOR SENSOR
DELIVERY TEMPERATURE CORRECTION AS A FUNCTION OF OUTSIDE
TEMPERATURE WITH RESPECT TO THE POSITION OF THE HEATING
TEMPERATURE CONTROL SET BY THE USER
TM-MAX/MIN = delivery temperature range selected
70
35
MIN
25
27 26
30
30
35
45
40
50
60
55
65
19
24
25
23
21
22
20
16
18 17
15 14
Tm
MAX
40
80
75
Te = Outdoor temperature
Tm = delivery temperature
-12
10
12 11
8
9
7
5
6
4
2
3
1
-6
-3
-1
0
-2
-4 -5
-9
-7 -8
-10 -11
8
9
7
6
5
0
Te (°C)
-15
-13 -14
1
2
3
4
Fig. 1
Fig. 2
Содержание RKR 24
Страница 2: ......
Страница 51: ...MAINTENANCE INSTRUCTIONS 48 POSITIONING THE IGNITION ELECTRODE AND THE IONISATION ELECTRODE 1 1 7 5 0 5 3 5...
Страница 64: ......
Страница 65: ......