REGULATION INSTRUCTIONS
35
PARAMETER
P07
–
CENTRAL
HEATING
TIMER
6. Use buttons ‘+’ and ‘-‘ to modify the value of the parameter
within the prescribed limits:
00 = 0 x 5” = 0”
90 = 90 x 5” = 450” (7,5 min)
The default value is 36 = 180” = 3 min
7. Press and release button ‘S’ to confirm. The parameter
number (P07) will appear on the display.
8. Switch off the appliance and switch it back on again to
render the new parameter operative.
PARAMETER
P08
–
CENTRAL HEATING PUMP
OVERRUN TIMER
6. Use buttons ‘+’ and ‘-‘ to modify the value of the parameter
within the prescribed limits:
00 = 0 x 5” = 0”
90 = 90 x 5” = 450” (7,5 min)
The default value is 36 = 180” = 3 min
7. Press and release button ‘S’ to confirm. The parameter
number (P08) will appear on the display.
8. Switch off the appliance and switch it back on again to
render the new parameter operative.
PARAMETER
P09
–
D.H.W
PUMP
OVERRUN
TIMER
6. Use buttons ‘+’ and ‘-‘ to modify the value of the parameter
within the prescribed limits:
00 = 0 x 5” = 0”
90 = 90 x 5” = 450” (7,5 min)
The default value is 18 = 90” = 1.5 min
7. Press and release button ‘S’ to confirm. The parameter
number (P09) will appear on the display.
8. Switch off the appliance and switch it back on again to
render the new parameter operative.
36
P 07
36
P 08
18
P 09