INSTALLATION INSTRUCTIONS
TA05A140.A0307
23
3.10.4
Flue type -
kit V
Vertical concentric flue kit Ø60/100 polypropylene inner pipe
.
Discharges exhaust fumes and draws air directly from high Level.
Suitable for condensing boilers
only.
Discharges exhaust gases and draws
combustion air at roof level by means of two
concentric ducts. The external Ø100 duct draws
the combustion air while the Ø60 plastic inner
duct discharges the exhaust fumes.
MAXIMUM FLUE LENGTH: 5 m.
The maximum flue length (linear equivalent)
is obtained by summing the length of linear
pipe and the equivalent lengths of each
bend fitted.
The
linear equivalent
is intended as being the
total length of the duct from the connection with
the combustion chamber of the appliance,
excluding the first bend.
The linear equivalent of additional bends is
as follows:
Ø60/100 x 90° = 0.8 m.
Ø60/100 x 45° = 0.5 m.
N.B.
:
USE ONLY RADIANT TYPE-APPROVED
FLUE SYSTEMS FOR DISCHARGING
EXHAUST GASES AND DRAWING
COMBUSTION AIR.
Ø100
Ø60
163
131
Ø60
Ø100
m
ax. 5.00 m
t.