REGULATION INSTRUCTIONS
TA05A140.A0307
35
P
ARAMETER
21
–
I
GNITION
S
EQUENCE
S
ETTING
6. Use buttons ‘+’ o ‘-’ to modify the value of the parameter
between: min = value of parameter 17; max = value of
parameter 18.
The default value is:
- 90 Hz for Natural Gas;
- 110 Hz for L.P.G.;
7
.
Press and release button ‘S’ to confirm. The parameter number
(21) will appear in the display.
8. Switch off the appliance and switch it back on again to render
the new parameter operative.
P
ARAMETER
22
–
F
AN
F
REQUENCY VALUE DISPLAY
6. Use buttons ‘+’ o ‘-’ to modify the value of the parameter: -
00 = Off
- 01 = On
If parameter value 01 is selected, during the boiler operation, the
display will show the fan frequency value for 10 min.
7. Press and release button ‘S’ to confirm. The parameter number
(22) will appear in the display.
8. Switch off the appliance and switch it back on again to render
the new parameter operative.
S
S
21
110
00
22
S
S