REGULATION INSTRUCTIONS
32
PARAMETER
P04
–
HEATING
OUTPUT
RISING
TIME
6. Use buttons ‘+’ and ‘-‘ to modify the value of the parameter:
00 = 0 seconds
01 = 50 seconds (default)
02 = 100 seconds
03 = 200 seconds
04 = 400 seconds
7. Press and release button ‘S’ to confirm. The parameter
number (P04) will appear on the display.
8. Switch off the appliance and switch it back on again to render
the new parameter operative.
PARAMETER
P05
–
WATER
HAMMER
PREVENTION
FUNCTION
(not applicable)
PARAMETER
P06
–
D.H.W
PRIORITY
FUNCTION
(not applicable)
00
P 06
00
P 05
01
P 04