2. FIRST START-UP
SUPPOR
T
CENTRE
PARAMETER
DESCRIPTION
RANGE
FUNCTION
P16
CLIMATE COMPENSATION CURVE
(ONLY WITH EXTERNAL PROBE CONNECTED)
YOU CAN CONNECT AN EXTERNAL TEMPERATURE
PROBE (SEE CHAPTER ‘ELECTRICAL
CONNECTIONS’) THAT AUTOMATICALLY CHANGES
THE DELIVERY TEMPERATURE BASED ON THE
EXTERNAL MEASURED TEMPERATURE. THE
NATURE OF THE CORRECTION DEPENDS ON
THE THERMO-ADJUSTMENT VALUE KD SET (SEE
CHART).
THE SELECTION OF THE CURVE IS DETERMINED
BY THE MAXIMUM DELIVERY TEMPERATURE TM
AND THE MINIMUM EXTERNAL TEMPERATURE TE
TAKING INTO ACCOUNT THE HOUSE INSULATION
DEGREE.
THE VALUES OF THE DELIVERY TEMPERATURES TM,
REFER TO STANDARD SYSTEMS 30-80 °C OR FLOOR
SYSTEMS 25-45 °C. THE SYSTEM TYPE CAN BE SET
FROM PARAMETER P03.
00 - 30
(SET BY DEFAULT AT 25) THE NUMBERING OF
THE VALUE CORRESPONDS TO ‘KD’ CURVES
ON THE CHART (SEE CHART BELOW).
P17
SET POINT
'
T DELIVERY-RETURN
(ONLY WITH MODULATING PUMP AND RETURN PROBE
CONNECTED)
THROUGH THIS PARAMETER YOU CAN SET THE
TEMPERATURE DIFFERENCE BETWEEN DELIVERY
AND RETURN.
00
00 = DISABLED
10 - 40
THE VALUE IS EXPRESSED IN °C
Te (°C)
35
30
25
20
15
10
75
80
45 MAX
Tm (°C)
5
0
-5
-10
65
55
60
50
40
45
35
30
30
-15
-20
25 MIN
35
70
Kd = 0
Kd = 5
Kd = 10
Kd = 15
Kd = 20
Kd = 25
Kd = 30